Maintenance
36
03.00 | SRH-plus-D | Assembly and Operating Manual | en | 1424337
7 Maintenance
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
7.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
7.2 Maintenance interval
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Interval [Mio. cycles]
for
SRH-plus-D 20 - 60
Maintenance work
Daily
Visually inspect the function of the shock
absorbers
Interval [Mio. cycles]
for
SRH-plus-D 20 - 40
Maintenance work
2
Clean all parts thoroughly, check for damage
and wear, if necessary replace seals and
wearing parts,
.
2
Treat all grease areas with lubricant,
2
Check that the shock absorbers are working,
if necessary replace shock absorber