Assembly
5.2.2 Pneumatic connection
NOTE
• Observe the requirements for the compressed air
supply,
.
• In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure
maintenance valve is recommended in this case in order to
maintain the dynamic effect for some time. Product variants
are also offered with mechanical gripping force via springs,
which also ensure a minimum clamping force in the event of a
pressure drop.
Air connections, variant with center position
Designation
Function
Hose-free direct connection
a
Swiveling 0° -90° / 0° - 180°
b
Swiveling 90° - 0° / 180° - 0°
c
Approach center position (M)
Extend locking position (VM)
d
Hose connection
A
Swiveling 0° -90° / 0° - 180°
B
Swiveling 90° - 0° / 180° - 0°
C
Approach center position (M)
Extend locking position (VM)
D
29