Maintenance
8.6.3 Dismantling and assembling rotary actuator (fluid feed-through)
1. Ventilate rotary actuator.
2. Remove all air connections,
3. Dismantle sensors if necessary.
4. Unscrew screws (7) and (11), remove clamp shell (10) and both
stop cover (8).
5. Mark the installation position of the pinion (1) and the pistons
(2).
6. Unscrew screws (6).
7. Remove flange (5).
8. Remove safety ring (4) on pinion (1).
9. Take pinion (1)out of the housing (9).
10. Take both pistons (2) out of the housing (9).
11. Assemble rotary actuator in the reverse order.
✓
Unless otherwise specified, secure all screws and nuts with
Loctite no. 243 and tighten with the appropriate tightening
torque.
63
04.00 | SRU-plus-D | Assembly and Operating Manual | en | 1380765