Assembly and installation
20
02.00 | SVH | Assembly and Operating Manual | en | 389734
NOTICE
Permanent damage to the electronics possible!
•
If the power supply is separated, carry out potential
equalization between the two supply voltages (join the
grounds).
•
Only the positive pole may be switched off; the GND motor
cable must always remain connected.
NOTE
In order to supply the hand with energy, a power supply unit must
be used that is able to supply sufficient power for the hand. Make
sure the dimensions of the cable cross-section are adequate when
cabling.
The assembly and installation of the SVH 5‐finger gripping hand
are different for the configurations listed below.
Operating on the assembly board
• Demonstration mode with SCHUNK Diagnostics and Control GUI
• Extended use on assembly board
• Free programming using the Mecovis software, for further
information see enclosed CD.
Operating on an external robot arm
• Mounting with the FWK11‐ISO flat change system
• Free programming
• The operator is responsible for the mechanical connection,
electrical connection and software used.