Troubleshooting
03.00 | Clamping Device SVP-2 | Assembly and Operting Manual | en | 0289021
21
Possible cause
Corrective action
Reduction insert not inserted up to the
stop into intermediate sleeve of the
clamping device.
Insert reduction insert up to the stop into the
intermediate sleeve of the clamping device.
Shank is too large.
Shank does not have the required
tolerance h6.
Use tool shank with tolerance h6.
Clamping pressure too low or too high
(wrong pressure value was entered).
Toolholder has already been over-
pressurized before.
Observe TRIBOS pressure table (do not exceed
max. pressure).
Clamping area dirty.
Keep clamping area clean.
Stickers or the like on the clamping area.
Keep clamping area clean at the outer
diameter. It must be possible to insert the
reduction insert properly.