Maintenance
104
12.00 | SWS | Assembly and Operating Manual | en | 389456
SWS
Change integrated piston stroke control
Ø
Place the SWA in the storage rack, secure and uncouple it.
Ø
Switch off the power supply and ensure that there is no residual
energy in the system.
Ø
Remove the compressed air hose.
Ø
Disassemble the SWK from the robot and safely set the SWK
aside,
Removing the product from the robot arm
Ø
Check sensor cable for damage, replace if necessary.
Ø
For retrofitting:
Remove the protective cover from the bores on
the SWK.
For replacement:
Loosen the mounting screws and remove the
sensor assembly with damaged sensor from SWK.
Ø
Secure the new sensor assembly lock (2) or monitoring of
unlocking (3) to the SWK (1) with screws (4).
✓
Max. tightening torque: 1.4 Nm
Ø
Connect cable to sensor assembly (2) and (3).
Ø
Lock and unlock the locking piston manually.
Ø
Connect all compressed air lines.
Ø
Switch on energy supply.
Ø
Lock and unlock the locking piston and check the signals of the
sensors.