Maintenance and care
02.00 | KSF3, KSF3-LH, KSF3-F | Assembly and Operating Manual | en |
1467140
31
•
Pull out the plug (81).
•
Unscrew the screws (84) and the fitting
screws (82) and disassemble the clamping
system from the machine table.
•
If using clamping sleeves (85), remove them
from the housing.
•
Remove screws (64) and take off the cover
strip (8).
•
Remove screws (66) and take off the guide
strip (6).
•
Variant "PM" also includes a compression
spring (27), O-ring (43), sphere (24) and O-
ring (42)
•
Remove the screw (69).
•
Remove chuck piston (3) and base jaws (2).
In the case of the PM variant, note that the
monitoring elements can fall off when the
base jaws are removed.