Assembly and connection
01.00|KSH3, KSH3-LH, KSH3-F |en
21
NOTE
• For vertical installation, the openings of the coolant drain (V)
must always face downwards
• Surface
"X"
is parallel to the guideway of the base jaws (item 2)
so the clamping force block can be aligned on the machine
table or to check the positioning.
Assembly with clamping sleeves:
Mount the clamping force block on the machine table together
with clamping sleeves (item 85) and screws (item 84).
Assembly with fitting screws:
There are two fittings in the housing (item 1) that, along with the
fitting screws (item 82), are used to center the clamping force
block on the machine table with repeat accuracy. Do not realign
the clamping force block after removing it from the machine table
(e.g., after replacing the seals). When using fitting screws (item
82), these are used instead of the clamping sleeves (item 85) and
two of the four screws (item 84).
Mounting with cylindrical pins (Z variant):
The clamping force block is fastened to the machine table with 4
screws (item 84). The two cylindrical pins (item 34) are used for
alignment with repeat accuracy. Do not realign the clamping force
block after removing it from the machine table (e.g., after
replacing the seals).