Trouble shooting
32
02.00|KSPplus-BWM KSP-LHplus-BWM |en
Trouble shooting
Clamping block chuck jaws will not move
Possible cause
Solution(s)
Air supply interrupted
Check air supply
System pressure too low
Increase system pressure according to clamping
system technical specifications
Connections incorrect
Connections incorrect Check connections and
functions and connect properly
Unused air connections are not sealed Seal front or base connections with accessories
(included in delivery)
Air connections in use are sealed
Remove set-screws from sealed air connections
Piston will not move
Possible cause
Solution(s)
Air is not oiled
Check maintenance unit, perform maintenance
Place oiler closer to clamping system
Set required oil level
Chuck piston screw broken (overload) Send clamping system to SCHUNK for repairs
or
Disassemble clamping system and repair with
original SCHUNK replacement parts
Piston rod or piston rod screw broken
(overload)
Send clamping system to SCHUNK for repairs
or
Disassemble clamping system and repair with
original SCHUNK replacement parts
Air connections in use are sealed
Remove set-screws from sealed air connections
Jaw changing function does not operate properly
Possible cause
Solution(s)
Lock bolt at changing interface not
re-setting and remains depressed
Check if motion kinematics can be easily moved
and if they are damaged.
To improve movement, apply a few drops of
machine oil to the rotating joints until the
kinematics automatically reset