Trouble shooting
02.00|KSPplus-BWM KSP-LHplus-BWM |en
33
Lock bolt on changing interface not
recessing
Check if motion kinematics can be easily moved
and if they are damaged.
To improve movement, apply a few drops of
ma-chine oil to the rotating joints
Repeat accuracy not achieved during
jaw change
Clean change interfaces and check for damage.
Replace damaged parts, if necessary.
The changing jaws have been switched.
Changing and base jaw numbers must match
Increased changing jaw "rear-up"
Clean interfaces between base and changing
jaws.
Set changing jaw firmly into change interface by
pulling backward
Clamping block does not make a complete stroke
Possible cause
Solution(s)
Chips or dirt between covering strip
and base jaws
Unscrew the covering strip (7) and remove chips
and dirt
Drop of clamping force
Possible cause
Solution(s)
Clamping block not tightly sealed
Check connection and seal screws and reseal or
replace
Seals damaged
and re-place all the seals (see seal kit list
Inadequate lubrication
Lubricate the lubrication nipples with
LINOMAX 200
Clamping block jerky
Possible cause
Solution(s)
Steel guide rollers on sliding surfaces
not lubricated