Maintenance
20
02.00 | TCU-Z | Assembly and operating manual | en | 389464
6 Maintenance
6.1 Notes
Original spare parts
Use only original spare parts of SCHUNK when replacing spare and
wear parts.
6.2 Maintenance and lubrication intervals
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.
Interval [Mio. cycles]
for TCU-Z
Maintenance work
50 - 100 125 - 160
200
4
3
2
Clean all parts thoroughly, check for
damage and wear, if necessary
replace seals and wearing parts
Servicing and assembling the
product
4
3
2
Treat all grease areas with lubricant
Lubricants/Lubrication points (basic
lubrication)
For extreme ambient and application conditions, shortened
maintenance cycles can ensure the lifespan is maintained.
CAUTION
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
•
Reduce the lubricant intervals accordingly.