Troubleshooting
8.5 Malfunctions when loading and unloading the change
interface with fitted cone seal
Possible cause
Remedial measures
Cone seal jams when being actuated
Remove cone seal from the module and clean
it
The pressed down cone seal does not
return to its original position
Remove cone seal and clean it. Check
components for damage.
Clamping area has been filled with
accumulated chips
Remove cone seal and clean it Clean clamping
pin holder, replace sealing ring Actuate exhaust
function for supplying compressed air
The cone seal is jammed
Check whether the thrust washer is installed in
the correct position on the mounting
A component is broken (e.g. due to
overloading)
Replace damaged component of the cone seal.
Check change interface of the module for
damage
Clamping pallet clamps when unlocking
the module from the change interface
Increase loading weight or pressure force.
8.6 The cone seal does not seal
Possible cause
Remedial measures
Sealing ring is damaged or deformed
Remove seal and replace sealing ring
Sealing ring is damaged
Initiate loading and unloading process only
when clamping slides are fully retracted
Sealing ring spreads too little when
closing the clamping module
Ensure that the components are installed in the
correct position
8.7 The media transfer unit of the NSE3 138-P is not working
Possible cause
Remedial measures
Coupling elements are not positioned
correctly in alignment to each other
Check the positioning of the pallet, connect it
so that it is aligned with the functions on the
module
Failure to observe installation
recommendation for coupling nipple in
clamping pallet
Check installation recommendation for the
coupling nipple
Clamping pallet is not resting flat on the
modules
Ensure that the media transfer units are
depressurized and ventilated
55
08.00 | NSE3 138, NSE-T3 138 | VERO-S quick-change pallet system | en |
1152197 -NSE3 NSE-T3