Function
5 Function
The item numbers specified for the corresponding individual
components relate to chapter drawings.
5.1 KVS 40 cone seal
The -K versions of the NSE3 and NSE-T3 quick-change pallet
systems are equipped with a cone seal to protect the change
interface. The sealing unit can be sunk spring-loaded and reset
when the module is unlocked.
The change interface is sealed when the clamping module is closed
without clamping pins. On the base, the cone seal has an air
connection to actuate a cleaning or air purge function. The seal
can be optionally retrofitted without removing the unit from the
installation space.
Note
The blow-out function must be actuated with the clamping module
closed without clamping pins. In this case, the blow-out air is
discharged at the sealing position, and in doing so, blows coolant
and chips from the bearing surface. When using this function, to
load the change interface, the quick-change pallet system must be
supplied with blow-out air before unlocking. When using the blow-
out function for air-purge face contact monitoring, the sealing ring
on the bearing surface of the module must be removed. A step-by-
step installation assembly makes retrofitting the multi-part sealing
unit easier
Note
If several clamping modules with a cone seal are fitted in a
clamping station, the clamping pallet to be installed or the device
must have a corresponding handling system so that no lifting
occurs.
49
08.00 | NSE3 138, NSE-T3 138 | VERO-S quick-change pallet system | en |
1152197 -NSE3 NSE-T3