Technical data
16
03.00 | NSL3 | VERO-S quick-change pallet system | en | 1155408
3 Technical data
Type
designation
ID
Holding force*
(M10 / M12)
Fmax **
Total pull
down force
without
turbo
FmaxT ***
Total pull
down force
with turbo
Weight
NSL3 150-V1-T 1323568
35 kN / 50 kN
8 kN
28 kN
7.0 kg
NSL3 200
1323569
70 kN / 100 kN
16 kN
---
16.9 kg
NSL3 200-V1-T 1323570
70 kN / 100 kN
16 kN
56 kN
16.7 kg
NSL3 300-200 1323571
105 kN / 150 kN
24 kN
---
27.8 kg
NSL3 400
1323572
140 kN / 200 kN
32 kN
---
35.7 kg
NSL3 600
1323574
210 kN / 300 kN
48 kN
---
54.4 kg
NSL3 800
1323575
280 kN / 400 kN
64 kN
---
73.2 kg
* Holding force when fastening the clamping pin with cylindrical
screw – DIN EN ISO 4762/12.9
** Total pull down force (total sum of pull-down forces of all the
clamping modules mounted in the clamping station)
*** Total pull-in force with TURBO function for clamping station
NSL3-V1 (total sum of pull-in forces with TURBO of all the clamping
modules mounted in the clamping station)
Minimum pressure
5 bar
Unlocking pressure
5 bar to 6 bar
Maximum pressure turbo function
6 bar
Repeatability [mm]
< 0.005 mm
Installation position
any
Operating temperature
+5 °C to +60 °C
Required level of cleanliness
IP 30 in accordance with DIN EN 60529
Noise emission [dB(A)]
≤ 70
Pressure medium
Compressed air, compressed air quality according
to ISO 8573-1: 7:4:4
IP rating
IP 67
The actuating pressure for the unlocking function must be set to at
least 5 bar up to a maximum of 6 bar.
The actuating pressure for the turbo function must not exceed 6
bar.