Maintenance and care
42
03.00 | NSL3 | VERO-S quick-change pallet system | en | 1155408
7 Maintenance and care
The clamping stations and integrated quick-change pallet system
are designed for low-maintenance operation, so that opening and
disassembling the fitted clamping modules is only necessary in
exceptional cases.
CAUTION
Risk of injury and risk of damage to the clamping module when
opening the housing cover.
If the clamping module has to be disassembled, send the
module to SCHUNK for repair.
The covers of the clamping modules are spring preloaded and
may only be removed by trained specialist personnel. The
covers can only be disassembled and assembled using a special
assembly tool and by observing the corresponding disassembly
and assembly instructions.
To ensure the quick-change pallet system operates perfectly, the
following instructions are to be observed:
Pressure medium: Compressed air, compressed air quality
according to ISO 8573-1:7 4 4
CAUTION
A separate maintenance unit with oiler must be used for the air
supply.
• Check the clamping station at regular intervals (at least every
two weeks or after 1000 clampings). The system is functioning
correctly if the clamping slides on all simultaneously actuated
clamping modules move smoothly at the minimum system
pressure of 5 bar and open completely.
• Carry out regular visual/functional checks. In case of visible
damage or signs of malfunction, shut down the quick-change
pallet system immediately.
The system may only be commissioned again once the faults
have been corrected. For example, by replacing the damaged
unit.
• During maintenance work on the quick-change pallet modules
or the bottom air supply of the clamping station, new seals
must be fitted and lubricated with Renolit HLT 2 or a similar
grease before assembly.