background image

 
 

 

1. Wiring for 4796

 

 

25

7

7

30

7

25

Cable guard

Cable Clamp

N

blue

Yellow / 

green

L

brown

Torque Value 
0.8Nm

Torque Value 
0.4Nm

Torque Value
0.4Nm

4796-0

1

XX:

cut for cables 
over Ø 8.5 mm

Cable end sleeves

(Optional, not enclosed)

 

 

Applicable Cable Types 
 

IEC

 

Type 

Cable Type

1)

 

Wire Size 

Cable Ø 

 

 

min.

2)

 

max. 

max. 

4796 

H05VV

 

-F 3G 

3x 1.00 mm

2

  3x 1.50 mm

2

  10.4mm 

H05RR

 

-F 3G 

3x 1.00 mm

2

  3x 1.50 mm

2

  10.4mm 

 

UL

 

Type 

Cable Type

3)

 

Wire Size 

Cable Ø 

 

 

min. 

max. 

max. 

4796 

SV… 

3x AWG 16 

3x AWG 16 

10.4mm 

SJ… 

3x AWG 16 

3x AWG 14 

10.4mm 

 

1) Harmonized w ire coding in accordance w ith IEC60227-5 respectively IEC60245-4. 
2) If cord has a length exceeding 2m, nominal cross -sectional areas shall be 1.0mm

2

 or more. 

3) Types according to UL 62 w hich begins with the given letters (i.e. SV… includes SV, SVT, SVE etc.).

 

 
 

 

1. Wiring for 4796

 

 

25

7

7

30

7

25

Cable guard

Cable Clamp

N

blue

Yellow / 

green

L

brown

Torque Value 
0.8Nm

Torque Value 
0.4Nm

Torque Value
0.4Nm

4796-0

1

XX:

cut for cables 
over Ø 8.5 mm

Cable end sleeves

(Optional, not enclosed)

 

 

Applicable Cable Types 
 

IEC

 

Type 

Cable Type

1)

 

Wire Size 

Cable Ø 

 

 

min.

2)

 

max. 

max. 

4796 

H05VV

 

-F 3G 

3x 1.00 mm

2

  3x 1.50 mm

2

  10.4mm 

H05RR

 

-F 3G 

3x 1.00 mm

2

  3x 1.50 mm

2

  10.4mm 

 

UL

 

Type 

Cable Type

3)

 

Wire Size 

Cable Ø 

 

 

min. 

max. 

max. 

4796 

SV… 

3x AWG 16 

3x AWG 16 

10.4mm 

SJ… 

3x AWG 16 

3x AWG 14 

10.4mm 

 

1) Harmonized w ire coding in accordance w ith IEC60227-5 respectively IEC60245-4. 
2) If cord has a length exceeding 2m, nominal cross -sectional areas shall be 1.0mm

2

 or more. 

3) Types according to UL 62 w hich begins with the given letters (i.e. SV… includes SV, SVT, SVE etc.).

 

owner

vettersa

creation date

22.10.2019

release date

22.10.2019

released by

vettersa

change order no

2018605

rev

G

page

1 of 2

0115.0049

Operation Manual

Wiring for 4796

Reviews: