INsTALLATION INsTRUCTIONs
ATTENTION!
T
his boiler is intended solely for the use for
which it was expressly designed. Any other
use is to be considered improper and there-
fore dangerous.
This boiler heats water at a temperature
lower than the atmospheric pressure boiling
temperature.
Before connecting the boiler, have professionally
qualified personnel:
a) Thoroughly wash all the piping of the sys-
tem to remove any residues or impurities
which could jeopardise proper operation
of the boiler, even from a hygienic point
of view.
b) Check that boiler is set up to oper-
ate with the available type of fuel.
This can be seen written on the package and
on the technical feature plate;
c) Check that the chimney/flue has an appropri
-
ate draught, without any bottlenecks, and that
no exhausts from other appliances are insert-
ed, unless the flue has been implemented to
accommodate several utilities according to
specific standards and regulations in force.
Only after this check can the fitting between
the boiler and chimney/flue be mounted;
ATTENTION!
If there is dust and/or if there are aggressive/
corrosive vapours present in the installation
room, the appliance must be protected
suitably and must be able to operate
independently from the air in the room.
ATTENTION!
Only mount the appliance on a closed wall, made
of non-flammable material, flat, vertical so that the
minimum distances required for installation and
maintenance can be observed.
The boiler must be connected to a central heating
system and/or domestic hot water supply network
compatible with its efficiency and output.
3.1 - GENERAL wARNINGs
3.2 - INsTALLATION sTANDARDs
t must be installed by a professionally qualified technician,
who
shall take the responsibility of observing all local and/or
national laws published in the official journal, as well as
the applicable technical standards.