Maintenance instructions
4.4 - PROGRAMMING THE OPERATING PARAMETERs
ATTENTION!
Function reserved for Authorised Assistance
Centres only.
The user is NOT authorised to activate the
function described below.
sE
sERvICE PARAMETER
Press the
BUTTON
simultaneously to enter in the service
mode SE and change value.
A
Operation READING PARAMETER
Press the
YELLOw
key to view default setting
B
Operazion CHANGE PARAMETER
Press key
+ (PLUs) / - (MINUs)
to modify
C
Operazion SET MODIFY PARAMETER
Press the
YELLOw
key
eBUs IDENTIFICATION CODE
eBUs IDENTIFICATION CODE
VALUE
FROM
TO
DEFAULT
0
10
0
BURNER MODULATION LEvEL IN IGNITION
Continue with the modification of parameters by pressing
the (MINUS)
Repeat the operations A-B-C to change value
VALUE
FROM TO
DEFAULT
BWA R 50
BWA R 70
0
99 Methane
60
55
0
99
Propane
60
45