E16
FREEZING
EXCHANGER (24)
Is detected, the freezing of the heat
exchanger. If the heating sensor detects
a temperature below 2 ° C, the burner
ignition is inhibited until the sensor detects
a temperature higher than 5 ° C.
Remove power supply, close the gas
valve, defrost the heat exchanger
carefully.
E01
INTERVENTION OF THE HIGH LIMIT
thermostat (10)
Press the reset button on the panel and
/ or verify that the thermostat or its con
-
nections are not interrupted
E12
HEATING SENSOR (11)
Damage to the sensor heating
Check the efficiency of the sensor
(see table Res / Temp) (Pr.4) or its
connections.
E30
PARAMETERS OF FACTORY
Alteration of the factory settings due to
any electromagnetic interference.
Press the reset button if the fault does
not clear, replace the board
E11
FLAME PARASITE
Flame detected in ignition
Check the wiring electrode Acc / Ril.
and remove any oxidation, press the
reset button, if the fault does not clear,
replace the electrode (4).
E20
FLAME PARASITE
Flame detected after shutdown
Check the wiring and leakage of the
gas valve (3) eventually replace Gas
Valve
E10
INTERNAL FAULT
Replace the control board.
REQUEST FOR MAINTENANCE
After 10,000 switching On or 2,000
hours of operation of the burner, boiler
needs servicing
The blink code (Sr) does not preventthe
normal operation of the boiler.
Service the appliance and subsequently
reset the counter by selecting “Cr” from
the parameters menù and introducing
the relevant resetting code.
Provisions for proper disposal of the product in accordance with Directive 2002/96/EC
At the end of its life cycle the product must not be disposed of as urban waste. It can be taken to a special
recycling centre managed by the local authorities, or to a dealer who offers this service.
Separate disposal of a domestic appliance avoids possible negative consequences for the environment and
human health deriving from inappropriate waste handling and allows the recovery of the materials of which
it is made, in order to obtain significant energy and resource savings.
Summary of Contents for BWA R50
Page 1: ...INSTALLATION AND SERVICING MANUAL R 50 R 70 BWA R 50 R 70 ...
Page 2: ...2 ...
Page 20: ...20 DOUBLE Ø 80 ...
Page 39: ......