77
General information
1.6 - TECHNICAL DATA PLATE
CE marking
The CE marking certifies that the boilers meet:
- The essential requirements of the gas appliance directive
(directive 2009/142/EEC)
- The essential requirements of the electromagnetic compat-
ibility directive (2004/108/EEC)
- The essential requirements of the efficiency directive (92/42/
EEC)
- The essential requirements of the efficiency directive (direc
-
tive 2006/95/EEC)
KEY:
1 = CE monitoring body
2 = Type of boiler
3 = Boiler model
4 = Number of stars (directive 92/42 EEC)
5 = (S.N°) Serial Number
6 = P.I.N. Product Identification Number
7 = Types of approved flue gas exhaust configurations
8 = (NOx) NOx Class
A = Heating circuit characteristics
9 = (Pn) Effective nominal output
10 = (Pcond) Effective output in condensation
11 = (Qmax) Maximum heat output
12 = (Adjusted Qn) Adjusted for rated heat output
13 = (PMS) Max. heating operating pressure
14 = (T max) Max. heating temperature
B = Domestic hot water circuit characteristics
15 = (Qnw) Rated heat output in domestic hot water function (if different to
Qn)
16 = (D) Specific D.H.W. flow rate according to EN 625 - EN 13203-1
17 = (R factor) No. of taps according to the declared amount of water (EN
13203-1)
18 = (F factor) No. of stars according to the declared quality of the water
(EN 13203-1)
19 = (PMW) Max. domestic hot water operating pressure
20 = (T max) Max. domestic hot water temperature
C = Eletrical characteristics
21 = Electrical power supply
22 = Consumption
23 = Protection rating
D = Countries of destination
24 = Direct and indirect countries of destination
25 = Gas category
26 = Supply pressure
E = Factory settings
27 = Adjusted for gas type X
28 = Space for national brands