22
External probe
connection (*)
- Predisposed on the terminal
board, terminals
sE
Danger!
Only a qualified technician may per
-
form the electrical installation.
Before performing connections or
The boiler is equipped with a power ca-
ble, boiler installation requires electric al
connection to the mains
power supply. This connection must be
made up to standard, as required the
regulations in force.
ON/OFF room
thermostat connection (*)
- Remove the jumper and con-
nect the room thermostat wires
between terminals TA 2.
- Connect the modulating thermostat
wire between terminals
TA1/OT
after having removed the jumper.
ON/OFF room
thermostat connection
RT/OT (*)
Remember that a bipolar switch must be
installed on the boiler power line with over
3 mm between contacts, easy to access,
making maintenance quick and safe.
The power cable must be replaced by
authorised technical staff, using original
spare parts only. Failure to comply with
the above can jeopardise the safety of
the appliance.
Electric power supply connection
3.9 - ELECTRICAL CONNECTIONs
any type of operation on electrical parts, always
disconnect electrical power and make sure that
it cannot be reconnected accidentally.
See par. 4.5 positioning on the board
(*) Optional