3 Operation
EN Floor grinding machine DSM 250
16
3 Operation
Risk of injury from parts flung out during grind
ing!
Wear protective clothing and protective goggles!
Wear safety shoes!
Wear protective gloves!
Proceed with the greatest care and caution!
Danger of injury from loud noise during grinding
operation of the machine! Emission value is
greater than 85 dB (A).
Always wear hearing protection when the ma
chine is in operation!
High-voltage electrical current can be fatal! Do
not allow the power line to be run over, crushed
or pulled on!
Risk of injury from dust formation during grind
ing work!
Connect an extractor unit to the machine or feed
in water during the grinding process.
Wear respiratory protection!
3.1 Starting up the machine
Observe the safety instructions in Chapter 2!
The initial start-up of the machine may be car
ried out only by qualified personnel!
A visual inspection of the machine needs to be
done before starting up the machine.
Particular attention should be paid to damaged
or loose components, wearing and filling levels.
Always use ETX diamond tools or abrasive bonding
for the surface to be machined (e.g. some surfaces
have to be ground wet).
1.
Check the surface to be ground and remove any
protruding objects.
2.
Loosen the clamping screw [15, Fig. D], adjust
the guide bar [3, Fig. D] to the appropriate work
position and retighten the clamping screw.
3.
Check ETX diamond tools for function and con
dition and replace if necessary.
(
!
Chapter 5.2 ‐ page 18).
4.
Place the grinding plate [22, Fig. E] with the in
serted ETX diamond tools [23, Fig. E] on the
surface to be ground.
5.
Turn the carriage height adjustment [10, Fig. B]
until the machine is aligned horizontally accord
ing to the built-in water level [6, Fig. B].
6.
either:
Prepare for standard floor grinding
(
!
Fig. K/L)
a.
Push cover [7] onto the slide plate [28].
b.
Turn suction ring [26] until the cover
latches into the safety hood [14, Fig. L left].
or:
Prepare for edge grinding
(
!
Fig. B/C/K/L/M)
a.
Pull cover [7] from the slide plate [28] and
insert into the holder [8].
b.
Turn the suction ring [26] with the slide
plate [28] to the corresponding edge side
(right or left) (
!
Fig. J].
c.
Loosen the clamping screw [12] by hand.
d.
Swivel the drive all the way to the appropri
ate side (right or left) (
!
Fig. J/M].
e.
Tighten clamping screw.
f.
Align slide plate [28] to the wall (
!
Fig. J/M
help lines).
7.
Attach external dust extraction (customer side)
at the connection to the dust extraction
[19, Fig. D].
8.
Check the safety equipment for completeness
and function before starting up!
Risk of damage due to tensile strain exerted by
the power line!
9.
Connect the line for the power supply of the ma
chine with the balancer [17, Fig. D].