3.3 GAS REQUIREMENTS AND LEAK TESTING:
PROPANE:
NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER.
PRECAUTIONS:
•
Periodically check the whole system for leaks or if the smell of gas is detected.
•
Extinguish all open flames. Perform ALL leak testing
outdoors
.
•
Never leak test while smoking.
•
If you can not stop a leak, turn off the gas supply and call a qualified and licensed technician, or
your gas supplier.
•
Only those parts recommended by the Manufacturer should be used. Substitution will void the war-
ranty.
•
Do not use the heater until all connections have been leak tested and are sound !!!
GAS REQUIREMENTS:
•
Maximum inlet pressure to propane regulator must not exceed 125 psi.
•
A Minimum supply pressure of 11.0” w.c. is required to maintain correct burner input.
•
The pressure regulator and hose assembly supplied with the appliance MUST be used. Any
replacement pressure regulator and hose must conform to standards & specifications of
Schwank and all local codes.
•
The installation must conform with local codes, or in the absence of local codes, with National Fuel
Gas Code.
3.4 Schwank Series 4001/2-J & 4401/2-J specifications:
•
Operating pressure 11” w.c.
•
Inlet gas supply pressure minimum 5psi / maximum 125psi
•
Maximum operating input rating 46,000 BTUH
•
Low fire input rating 26,500 BTUH
•
Effective radiant range 8 to 20 foot circle (effected by wind and ambient
temperature)
•
Fuel Propane
•
Cylinder size 30 lb or 20 lb.
(cylinder not included)
•
Fuel consumption 30 lb. cylinder 15 hours at maximum setting
20 lb. cylinder 10 hours at maximum setting
(ambient temperature effects rate of fuel delivery)
•
Net Weight 60 lbs not including cylinder.
•
Certifications CSA International USA and Canada