background image

 

4SN/L5,4BN/L6 Manual

,0

 

    RD: JUNE 2008  

RL: 1A 

BA 

 

NOTICE:

 

 

The Manufacturer. reserves the right to make changes to equipment  
and specifications without obligation or notification. 
 
This publication, or parts thereof, may not be reproduced in any form 
without prior written consent from the manufacturer.   
Unauthorized use or distribution of this publication is strictly prohibited. 
 
Schwank Group / InfraSave  
5285 Bradco Boulevard 
Mississauga, Ontario,  
Canada  L4W 2A6 
 
PO Box 988, 2 Schwank Way 
Waynesboro, Georgia, 
USA  30830 
 
Phone: 1-877-446-3727 
Fax: 1-866-361-0523 
 
e-mail: csr@schwankgroup.com 
 

www.patioSchwank.com

        

www.InfraSave.com

 

Summary of Contents for InfraSave 4BL6

Page 1: ...ish any open flame Don t touch any electrical switch or telephone Go to a neighbor and call your gas supplier immediately Follow any and all instruction from your gas supplier If your gas supplier is...

Page 2: ...may not be reproduced in any form without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited Schwank Group InfraSave 5285 Bradco B...

Page 3: ...51 62 SPECIFICATIONS 2 3 2 4L51 62 SPECIFICATIONS 3 4 MAIN COMPONENTS FOR ASSEMBLY 4 5 ASSEMBLY INSTRUCTIONS 5 6 CONNECTION AND TESTING 8 TOPIC PAGE NUMBER 7 SAFE LOCATION FOR HEATER 9 7 1 CLEARANCE F...

Page 4: ...l Gas 4SN5 and 4BN6 or Pro pane 4SL5 and 4BL6 The burner is controlled and adjusted by the gas control knob at the top of the heater and the gas supply is fed up through the inside of the pole using f...

Page 5: ...d Substitution will void the warranty Do not use the heater until all connections have been leak tested and are sound GAS REQUIREMENTS Maximum inlet pressure to heater must not exceed 5 w c Heater man...

Page 6: ...nlet pressure to propane regulator must not exceed 125 psi A Minimum supply pressure of 11 0 w c is required to maintain correct burner input The pressure regulator and hose assembly supplied with the...

Page 7: ...t if mounting on concrete patio Teflon Plumbing Tape for Joints Spray Bottle of Soapy Water or Paint Brush and soapy water to check leaks Models 4SN L5 include stainless post and base Models 4BN L6 in...

Page 8: ...ecure using screws Feed the gas hose provided either down from the top of the post or up through the side opening at the bottom of the post If inserted from the top push the gas hose all the way down...

Page 9: ...affixed to the burner assembly HAND TIGHTEN the fastening screws at this time When the heater is connected to the gas supply the burner head will need to be lifted to leak test the hose connection to...

Page 10: ...loor Tighten the nuts down tight and the stud threads will get longer Remove the nuts and washers leaving 3 x threaded studs sticking out of the concrete ASSEMBLY CONTINUED Bolt 3 bolts down into the...

Page 11: ...leak Close gas supply valve completely Retighten the leaking connection and repeat leak test process until ALL leaking has ceased no matter how small If the leak cannot be repaired permanently close t...

Page 12: ...only Always maintain minimum clearances to combustibles as shown in figure 12 below Install heater on a level solid and stable surface Do not install in an explosive environment Keep away from areas...

Page 13: ...counter clockwise TO TURN OFF 1 Turn the knob clockwise until it stops 2 Depress knob and turn fully clockwise to shut of the gas supply completely Warning A 5 minute complete shut off period is requ...

Page 14: ...pressure is low Spider or insect cocoon Check gas pressures with ma nometer Check for restricted or plugged orifice Burner Unit Carbon on reflector emitter screen or thick black smoke Clean component...

Page 15: ...mage the reflector may be removed and stored separately in a secure location 9 2 PREVENTATIVE CARE AND MAINTENANCE The burner area is likely to attract spiders especially inside the gas orifice Regula...

Page 16: ...er This warranty does not cover heating products improperly installed misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact a...

Reviews: