background image

lunaSchwank 

 Technical Instructions 

 

 

General

 

Setup and functioning of this gas-infrared heater 
conform to the applicable standards and safety 
regulations in the European Union. 
 
We request you to read this technical instruction 
carefully before using the device. Following the 
instructions and information mentioned here is a 
prerequisite for our warranty and is necessary for 
enabling a proper installation and a fault-free 
operation. 
 
The high-power heater lunaSchwank is meant 
exclusively for heating open areas and well 
ventilated rooms. Any other use or a use over and 
above this is considered as improper. SCHWANK 
GmbH will not be liable for resulting damages. The 
user alone will bear the resulting risk. 
 
 

Safety instructions 

This device is built according to state-of-the-art 
technology and the legally recognised safety rules. 
Still, in case of improper use, there can be hazards 
for the user or for a third party or an impairment of 
the device and loss of other assets.

 

 

General safety instructions

 

 

 

Use the device only in the proper way and in a 
technically fault-free state. 

 

Make sure that all persons operating, 
mounting, installing, commissioning, servicing 
or repairing this device have read the technical 
instruction. Please preserve the technical 
instruction at the place of use. 

 

Pay attention to the generally applicable legal 
and other binding rules of accident prevention. 

 

Do not make any changes or build structures 
on or around the device without the explicit 
permission of SCHWANK. 

 

All spare parts must conform to the technical 
requirements. For this reason, use only the 
original spare parts. 

 
 
 
 
 
 
 

Safety instructions for electrical 
equipment 

 

 

Electric shock hazard! 
You can get fatally wounded through electric 
shocks. 

 

Work on the electrical equipment of the device 
may be done only by a skilled electrician in 
accordance with the electro-technical rules. 

 

Regularly check the electrical equipment. 
Braised cables, etc. must be replaced 
immediately. 

 

Switch the device free of voltage when working 
at the electrical equipment. Safeguard the 
device against an unintentional switch-on. 

 

Safety while working with the device

 

 

Mounting, installation, initial commissioning, repair 
and maintenance work may be done only by a 
contractual installation company [VIU] qualified and 
authorised for this.  
 
If you have any queries, please get in touch with 
the respective customer service of SCHWANK. 

 

Safety during mounting and 
installation 

 

 

Please follow the TECHNICAL RULES, 
worksheet G 638/I of DVGW.  

 

According to G 638/I, the initial commissioning 
may be done only by the manufacturer or by 
an authorised VIU. 

 

Fire hazard!  
Please adhere to the safety distances [see 
page 4 and 5] during mounting, see to it that 
the ignition device is easily accessible. 

 

Lay the gas and electrical lines in such a way 
that they cannot get heated by the rising 
exhaust gases or by the direct heat radiation. 
Only the heat-resistant cables may be used 
near the heater.

 

 
 
 
 
 
 
 

Summary of Contents for lunaSchwank 12

Page 1: ...Patio gas infrared heater 6 9 12 with 2 stage modulation Image Heater lunaSchwank 6 Technical Instruction 0085CS0486 Document version dated 02 03 2018 Subject to technical changes...

Page 2: ...bH Bremerhavener Str 43 50735 Cologne P O Box 62 02 49 50695 Cologne Tel 49 0 221 7176 0 Fax 49 0 221 7176 288 Internet www schwank de Belgium China France Great Britain Canada Netherlands Austria Pol...

Page 3: ...ces to combustible materials 6 Connections and dimensions 8 Operation 11 Setting the nominal heat load 12 Repair maintenance 13 Technical operating data 15 Electrical connection plan 17 Mounting the h...

Page 4: ...accident prevention Do not make any changes or build structures on or around the device without the explicit permission of SCHWANK All spare parts must conform to the technical requirements For this r...

Page 5: ...which can be found in the enclosed bag Adjust the preferred radiation angle by fixing the screw 25 45 Gas installation Always mind the following indications when installing the gas piping a Always ins...

Page 6: ...wank 9 Min 810 mm Min 650 mm lunaSchwank 12 Min 850 mm Min 800 mm Device type with hood Distance B Distance C lunaSchwank 6 Min 450 mm Min 600 mm lunaSchwank 9 Min 560 mm Min 650 mm lunaSchwank 12 Min...

Page 7: ...nce B Distance C lunaSchwank 6 Min 400 mm Min 600 mm Min 700 mm lunaSchwank 9 Min 500 mm Min 670 mm Min 850 mm lunaSchwank 12 Min 600 mm Min 700 mm Min 1000 mm Lateral safety distance 280 mm lunaSchwa...

Page 8: ...4 2 kW 50 mbar 0 28 kg h Butane G30 6 4 2 kW 50 mbar 0 28 kg h Weight without cladding 14 kg Weight with cladding 19 kg Burner 8 16 with ceramic plates 14 4 EF Scope of delivery lunaSchwank 6 Gas magn...

Page 9: ...9 6 3 kW 50 mbar 0 28 kg h Butane G30 9 6 3 kW 50 mbar 0 28 kg h Electrical connection Single phase alternating current 230 V AC 50 Hz 45 VA Weight without hood 16 5 kg Weight with hood 22 kg Burner 8...

Page 10: ...mbar 0 52 kg h Butane G30 12 8 4 kW 48 mbar 28 mbar 0 52 kg h Electrical connection Single phase alternating current 230 V AC 50 Hz 45 VA Weight without hood 19 kg Weight with hood 25 kg Burner 16 2...

Page 11: ...h off 1 Switch off the heater at the switching box 2 Close the shut off valve in case of long period of non use Malfunctions No ignition spark available No voltage is present Automatic ignition igniti...

Page 12: ...n pressure The connection pressure must be at least 2 mbar higher than the necessary nozzle pressure Fig 1 2 Stage magnet valve Turn off the test nipple again Check after each measurement whether you...

Page 13: ...bar higher than the set nozzle pressure Repair maintenance Regular maintenance is the prerequisite for the smooth operation of the heating system You can contact the Schwank customer service for this...

Page 14: ...of the air baffle plate till the cam a slides over the margin of the connecting piece and take out the air baffle plate Push the new air baffle plate A on the connecting piece till the fin is present...

Page 15: ...urner Identification 9 Natural gas H 2 E 2 H 9 0 5 9 20 18 7 8 2 25 28 0 26 2 Natural gas L 2 L 9 0 6 3 20 18 8 8 2 50 32 50 0 26 2 Propane 3P 9 0 6 3 50 47 23 1 40 50 24 Butane 3 B P 9 0 6 3 50 47 23...

Page 16: ...17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 11 0 11 5 12 0 12 5 13 0 13 5 orifice pressure hPa Wobbe index kWh m Pressure Wobbe graph natural gas L 13 0 14 0 15 0 16 0 17 0 18 0 19 0 20 0 21 0 22 0...

Page 17: ...lunaSchwank Technical Instructions 17 Electrical connection plan lunaSchwank 6 9 and 12 2 stage regulation...

Page 18: ...l Instructions 18 Mounting the hood Hood Spare parts Device Article No Name Device Item number Name of item 6 9 12 121 02503 Pilot burner set lunaSchwank natural gas 6 9 12 121 02504 Pilot burner set...

Page 19: ...lunaSchwank Technical Instructions 19 EC Type examination certificate...

Page 20: ...lunaSchwank Technical Instructions 20...

Page 21: ...lunaSchwank Technical Instructions 21 EC Declaration of conformity...