lunaSchwank
Technical Instruction
5
Mounting and commissioning
Attention!
The heater is only to be installed
outside or in well ventilated indoor
applications and may only be used
for heating purposes.
The heater may not be installed in
housing or office facilities or similar.
Installation area
The installation area has to provide a natural
air exchange rate from 1.5 per hour or more.
Suspension / Fastening
The heater is designed to be exclusively
mounted on walls or ceilings.
The heater is to be installed either on a rain
protected location or beneath a canopy in
combination with the respective wall or ceiling
suspension.
Start the mounting by fixing the wall suspension
to the wall. Mind the safety distances to the
ceiling and the sides.
In case you want to attach a heat protection
hood, first attach the hood suspension to the
heat protection hood. Than mount the
assembled heat protection hood the wall
suspension.
Attach the heater to the wall suspension and
close it. Than secure the heater with the black
screw with hexagon socket M8 X 90, which can
be found in the enclosed bag. Adjust the
preferred radiation angle by fixing the screw
[25-45°].
Gas installation
Always mind the following indications when
installing the gas piping.
a) Always install the heater with a stainless
steel flex tube with admission for the
respective area of application.
b) Never mount the heater by fixing it to the
gas piping.
Schwank offers a gas connection unit which is
designed for the heater and contains a
stainless steel flex tube with shut-off valve and
TAE.
Avoid the flex tube to be twisted
when mounting [When fixing the
connection, hold the equivalent on
the tube site].
The flex tube is to be protected from
mechanical damages before being
mounted [sharp kinking,
impressions by tools etc.]
Damaged flex tubes are not to be
installed, as they may tore caused by
motions of the heater.
Electrical installation
Install the electrical connections on the heaters:
main connection on the controller and main
connection on the plug of the solenoid.
The ignition wire and the ionisation wire are
already pre-mounted to the ignition controller.
Commissioning
Check the gas pressure:
Natural gas: 20 mbar
LPG: min. 50 mbar
Check the tightness of all gas connections
Now put the heater into operation and check all
functions.