lunaSchwank
Technical Instructions
8
Connections and dimensions
lunaSchwank 6
Gas connection:
Burner Rp 1/2
’’
[inside], hose Rp 1/2
”
[inside]
Gas type / Nominal heat load
Natural gas L [G25]
/ 6
–
4.2 kW / 20 mbar / 0.41 m³/h
/ Connection pressure:
Natural gas H [G20]
/ 6
–
4.6 kW / 20 mbar / 0.35 m³/h
/ Consumption
Propane [G31]
/ 6
–
4.2 kW / 50 mbar / 0.28 kg/h
Butane [G30]
/ 6
–
4.2 kW / 50 mbar / 0.28 kg/h
Weight without cladding:
14 kg
Weight with cladding:
19 kg
Burner:
8/16 [with ceramic plates 14/4 EF]
Scope of delivery:
lunaSchwank 6
Gas magnet valve with automatic gas firing, pilot burner, ignition cable, ionisation cable
Main connection for ignition & control unit
Wall bracket for wall mounting
Accessories:
Heat-protection hood with holder for wall mounting
Gas connection unit with TAE ball valve, connection Rp 1/2
”
, length 500 mm
Rp1/2
”