lunaSchwank
Technical Instructions
9
lunaSchwank 9
Gas connection:
Burner Rp 1/2
’’
[inside], hose Rp 1/2
”
[inside]
Max. connection pressure:
100 mbar
Min. connection pressure:
Natural gas H / L: 20 mbar, propane / butane: 50 mbar
Gas type/ Nominal heat load
Natural gas L [G25]
/ 9
–
6.3 kW / 20 mbar / 0.41 m³/h
/ nozzle pressure:
Natural gas H [G20]
/ 9
–
5.9 kW / 20 mbar / 0.35 m³/h
/ Consumption
Propane [G31]
/ 9
–
6.3 kW / 50 mbar / 0.28 kg/h
Butane [G30]
/ 9
–
6.3 kW / 50 mbar / 0.28 kg/h
Electrical connection:
Single phase alternating current 230 V AC, 50 Hz, 45 VA
Weight without hood:
16.5 kg
Weight with hood:
22 kg
Burner:
8/16 [with ceramic plates 14/4 EF]
Scope of delivery:
lunaSchwank 9
Gas magnet valve with automatic gas firing, pilot burner, ignition cable, ionisation cable
Main connection for ignition & control unit
Wall bracket for wall mounting
Accessories:
Heat-protection hood with holder for wall mounting
Gas connection unit with TAE ball valve, connection Rp 1/2
”
, length 500 mm
Rp1/2
”