Page 11
Hold diffuser
against board
and push upwards
Toggle clip snaps
into place holding
diffuser firmly
Operation of toggle clips
4. Installation
Figure 2 Ventilation Option for Dual Vent
BRW622 Duel Vent System or optional DVK600 Installation
To main
power/switch
Y-branch
Additional dual vent kit, Y-branch,
3 metre length flexi ducting and
inlet grille (Kit model no: BRW622
or DVK600)
For bathroom installation, locate inlet
over shower recess
2m of ducting
2m of ducting
Reducer
Bell-mouth Adaptor
For dual installation, bathroom, toilet or laundry
Back Draft Stopper
• Do not reduce the ducting size. 150mm must be used. Reducing the ducting will reduce extraction
• No sharp bends in the ducting
• Do not kink the ducting
• keep the amount of bends in the ducting to 2 or 3
• Do not use semi-rigid or solid ducting
IMPORTANT