Securing Flexible Duct

Flexible duct must be installed with supports at maximum intervals of 1.5 metres. Flexible ductwork can be 
supported by using gaffer or electrical tape, provided that it does not restrict the internal diameter of the 
ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the 
changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2. 

NOTE:

 Ducting should be kept taut at all times.

Figure 9 Examples of securing ducting

Option 1

Secure the flexible duct 
to the beam

Option 2

Support flexible duct 
by using hangers.

NOTE:

 Care shall be 

taken to minimize 
sagging or snaking 
of the duct between 
supports.

Aluminium foil 

tape or cable tie

Aluminium foil tape or 

cable tie

Hanger

6. Flexible Ducting 

Summary of Contents for BRW600

Page 1: ...INSTALLATION GUIDE BRW600 BRW622 www schweigen com au Revision V4 06 12 21 ...

Page 2: ...tant safety notes This will ensure your personal safety and the lasting value of your motor system We trust that you will enjoy your new Schweigen BRW600 system Please always retain your proof of purchase to aid in any warranty queries This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the env...

Page 3: ...____________________________ 6 Why Flexi duct __________________________________________________________________________________ 6 4 Roof Installation 1 Roof Installation ______________________________________________________________________________ 7 2 Eaves Installation _____________________________________________________________________________ 9 3 Wall Installation ___________________________...

Page 4: ...ailure to adopt proper safety measures Ensure that the location in which this appliance is installed has good and permanent ventilation Please consult local laws and regulations and install in accordance Use an electrical connector with earth that is correct for your location Check that the voltage in your area corresponds to the appliance as indicated on the rating label Electrical Cord Ensure th...

Page 5: ...e as the initial connection duct to the fan module and is supplied with a 100mm PVC pipe to 150mm flexible duct bell mouth adaptor This fan is suitable for connection to multiple duct runs with a minimum inlet area of 11 000 mm Ducting runs should be more than 2 metres away from the unit and no more the 4 5 metres check with supplier if longer duct length required Flexible ducting must be extended...

Page 6: ...ully flexible ducting The use of a complete rigid or semi rigid ducting system will cause an organ piping effect to occur like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplified out the other The motor system puts the noise outside the house Warning Installation without the use of at least the minimum recommended length of acoustically matched flexi...

Page 7: ...unted either vertically or perpendicular to the roof cladding with the roof penetration being sealed using a Dektite or other sealing device Please note Schweigen do not provide any sealing kits Ensure that the pipe protrudes at least 80mm past the top of the Dektite checking that the mounting flange clears the roof cladding at upper edge as shown in figure 1 The maximum recommended protrusion is ...

Page 8: ...nge Dektite Roof Frame 110mm PVC Pipe Secure pipe to structure 150mm flexible ducting 5 metre max Power cord Bell mouth adaptor Slot pipe for power cord exit Cover with ducting tape if required Optional bend Slot option Please refer to page 12 Figure 6 for back draft shutter fitment ...

Page 9: ...ce Remember to run power cord through the assembly and out the slotted PVC pipe wall figure 4 Fit the fan module to mounting flange by placing in position rotating clockwise to engage bayonet fingers then secure by screwing in locking screw while holding fan module firmly in the fully clockwise position Ensure that one of the three bayonet fingers is accessible for securing locking screw Bell mout...

Page 10: ...limited but if unrestricted Refer to EAVES INSTALLATION and figure 5 Figure 5 Min 20mm NOTE Ensure that power cord is fed through exit slot and is not allowed to double back restricting fan inlet Flexible 150mm ducting Bell mouth Adaptor Min 90mm long PVC pipe Please refer to page 12 Figure 6 for back draft shutter fitment ...

Page 11: ...nch 3 metre length flexi ducting and inlet grille Kit model no BRW622 or DVK600 For bathroom installation locate inlet over shower recess 2m of ducting 2m of ducting Reducer Bell mouth Adaptor For dual installation bathroom toilet or laundry Back Draft Stopper Do not reduce the ducting size 150mm must be used Reducing the ducting will reduce extraction No sharp bends in the ducting Do not kink the...

Page 12: ...system cannot be installed in eave type installation Figure 6 Figure 7 Back draft shutter system Bell mouth adaptor Fit flexi duct over shutter assembly Tape over flanges 100mm pipe to fan Direction of airflow To fan IMPORANT If shutter system is mounted in the horizontal position shutter shaft should be vertical Part number 150 MMBDSS Back draft shutter system Tape over flanges Air flow ...

Page 13: ...stallation will result in a service fee directed to the customer Schweigen will take no responsibility for problems caused by faulty installation Installation must be carried out by a qualified technician A preferred installer list can be obtained from Schweigen website www schweigen com au Please do not crush or kink flexible ducting as it will reduce air flow and may cause noise to occur through...

Page 14: ...Page 14 6 Flexible Ducting Shallow Roof Space In shallow roof spaces 90 degree elbow PVC joint can be used as a substitute for the bend ...

Page 15: ... installed in such a manner as to ensure the changes of direction are gradual Support of the ducting with the use of hangers may be required see option 2 NOTE Ducting should be kept taut at all times Figure 9 Examples of securing ducting Option 1 Secure the flexible duct to the beam Option 2 Support flexible duct by using hangers NOTE Care shall be taken to minimize sagging or snaking of the duct ...

Page 16: ...efore roof restoration or cleaning please completely cover the outside motor system and avoid all chemical contact IMPORANT Any damages caused by the use of chemical products are not covered by warranty Figure 10 Avoid chemical contacted to motor system ...

Page 17: ...Page 17 Vent 8 Measurements 303 200 194 35 255 89 303 52 7 35 8 44 5 150mm reducer 255 x 255 Ceilling Two timber support batons by installer 194 25mm outlet 240 x 240 ...

Page 18: ...Page 18 8 Measurements 157 278 35 minimum 370mm BRW600 Motor 195 28 110 35 29 Please refer to page 12 Figure 6 for back draft shutter fitment ...

Page 19: ...ting contact Customer Service In Australia Customer Service 1300 881 693 In New Zealand Customer Service 0800 200 510 Lodging an online Service Request In the event that failure is not due the reason s in the trouble shooting section you can lodge an online Service Request To lodge a Service Request visit our website www schweigen com au pages support service warranty and click on the link to down...