Page 12
4. Installation
Figure 2 Roof mount option
Twin 200mm Outlet Installation Example (3200 kit required)
This is for use where one motor is to be used and there are two 200mm outlets.
Try to keep length of
SteelFlex
™
ducting as
even as possible other
wise motors will draw air
off each other
Ensure SteelFlex
™
ducting
is fully extended and as
short as possible. Use
smooth flowing curves for
maximum air flow. Remove
excess ducting by trimming
to length.
250 x 200 x 200mm
If multi-fit Y joint supplied you
will need to cut to correct size.
3200 motor
200mm
SteelFlex
™
duct
250mm SteelFlex
™
ducting
200mm SteelFlex
™
ducting
200mm outlet
250
200
200