5. Measurements

Measurements for Isodrive 3200 

(Not to Scale)

5. Measurements

  400 

 288 

  250.5 

 440 

  342 

 15.7 

 50 

Figure 3

Dimensions in mm

Isodrive 3200 weighs 
8.3 kg without the PVC 
pipe.

Summary of Contents for Isodrive 3200

Page 1: ...INSTALLATION GUIDE Isodrive 3200 www schweigen com au Revision V4 25 11 21 ...

Page 2: ... unit as well as important safety notes This will ensure your personal safety and the lasting value of your Isodrive system Please always retain your proof of purchase to aid in any warranty queries This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environment by using the appliance effic...

Page 3: ...______________________________________ 7 Installation Roof Installation ________________________________________________________________________________ 9 Through Wall Installation_____________________________________________________________10 Twin 200mm Outlet Installation Example 3200 kit required _________________________________12 Optional Back Draft Shutter Installation Through Roof__________...

Page 4: ...as indicated on the rating label Before Installation We recommend this appliance to be installed or repaired by a qualified Schweigen Home Appliances technician Please see our website www schweigen com au for recommended installers It is dangerous to modify any part of this appliance Modification of any kind will immediately void the warranty Electrical Cord Ensure the supply cord is not exposed t...

Page 5: ...ial connection duct to the fan module and is supplied with a 250mm ISD PVC pipe and 250mm ISD SteelFlex see page 17 for installation details This fan is suitable for connection to multiple duct runs with a minimum inlet area of 22 000mm2 When installing 15 metres of the 250mm SteelFlex ducting MUST be used and no more than 2 to 3 bends in the ducting Where possible SteelFlex ducting must be extend...

Page 6: ...ex is antimicrobial treated thermally insulated and acoustically dampened It is fireproof pest and crush proof with a treated surface that prevents the build up of grease and bacteria Schweigen s unique Isodrive system works in the opposite way to conventional rangehoods pulling air through the hood and acoustically matched ducting producing almost silent high volume flow The use of a complete rig...

Page 7: ...head screws 7 250 200mm reducer only use when connecting the Isodrive 3200 motor to a single 200mm opening on a rangehood Not included in the box Roof seal kit Dektite Support straps for poly pipe which connects to the roof truss Aluminium foil tape Wall Mounting Kit 1 5 2 3 4 6 7 NOTE For more SteelFlex ducting instructions refer page 17 1 OD refers to outside dimension Included with the 3200 Kit...

Page 8: ...e slotted PVC pipe for connection to the female plug coming from the canopy rangehood Refer to figure 1 Do not insert plug into socket outlet or switch on until installation has been completed Fit fan module to pipe and fix in position using side locking screw Certain external installation configurations may cause audible levels of noise to be heard due to the air being expelled from the motor To ...

Page 9: ...nnect to power supply Only use when connecting the motor to a single 200mm outlet on the rangehood NOTE Prevent any cord bunching by pulling cord through from plug top end 250mm SteelFlex duct minimum 4 metres ducting length fully extended Dektite 250mm PVC Pipe Power cord Fix pipe to fan module with side locking screws Fit side supports to locate Strap to supports 50mm Pipe protrusion above ...

Page 10: ...unting kit Ensure power cable pipe and cover plate slot is at the bottom Wall cover plate Optional Part Number P2025 Power cable Through Wall Installation Mounting points Connecting pipe NOTE Make sure that the connecting pipe is well supported at least 2 mounting points recommended 4 Installation 40mm Wall ø 250mm 70mm End of pipe ...

Page 11: ...ed fastening holes first before installing Install fan unit last Ensure slot cover plate power cable and pipe slot is at the bottom Fix pipe to structure or with a strapping bracket Mounting points Wall cover plate Optional Part Number P2025 4 Installation 70mm ...

Page 12: ...ing as even as possible other wise motors will draw air off each other Ensure SteelFlex ducting is fully extended and as short as possible Use smooth flowing curves for maximum air flow Remove excess ducting by trimming to length 250 x 200 x 200mm If multi fit Y joint supplied you will need to cut to correct size 3200 motor 200mm SteelFlex duct 250mm SteelFlex ducting 200mm SteelFlex ducting 200mm...

Page 13: ...m end of the ducting 3200 motor PVC Storm pipe Cut existing ducting to 150mm to 200mm length Attach ducting to back draft shutter and secure with duct tape and clamp Shutter System Reducer Assemble ducting to bottom end of back draft shutter and secure with duct tape and clap see NOTE 150mm to 200mm 250mm SteelFlex ducting NOTE Ensure the flaps open upwards before assembling ducting to bottom end ...

Page 14: ...l Assemble existing ducting to the end of shutter system and secure with duct tape and clamp see NOTE Ensure that power cable passes through the cover palte notched recess and is clear of cut edge Wall cover plate with notch at bottom optional part NOTE Through wall installations flap shaft will be close to vertical and ensure flaps open towards the fan unit Minimum pipe protrusion from wall surfa...

Page 15: ...tic cover from Weather Shield and bend to form a circle Fasten P1128 Screws with P1128N Nuts at location shown Step 3 Place Mounting Brackets on to Fan Guard and fasten 2 pieces of P1124 as shown Ensure orientation of Bracket is mounted as shown Step 4 Repeat Step 3 for the rest of the Brackets Step 5 Mount Weather Shield and align mounting holes with the Brackets and fasten with P1124 5 areas P11...

Page 16: ...Page 16 5 Measurements Measurements for Isodrive 3200 Not to Scale 5 Measurements 400 288 250 5 440 342 15 7 50 Figure 3 Dimensions in mm Isodrive 3200 weighs 8 3 kg without the PVC pipe ...

Page 17: ...tion may reduce airflow or increase noise levels Call outs relating to incorrect installation will result in a service fee directed to the customer Schweigen will take no responsibility for problems caused by faulty installation A list of preferred Schweigen installers can be obtained from the Schweigen website www schweigen com au Please keep the SteelFlex ducting taut 4 to 5 metres in length is ...

Page 18: ...d Parts required 1 SteelFlex safety ducting 2 Steel ring clamp 3 20mm self drilling button head screws 4 250mm PVC riser pipe 1 2 4 3 NOTE Do not use duct tape to fasten the duct the screws and hose clamp are adequate to secure the duct to the riser pipe 2 Secure duct to the riser pipe at regular intervals with 4 x 20mm button head screws 3 Slide the steel ring clamp back up and tighten to secure ...

Page 19: ...ade of PVC or galvanise can be used as a substitute for the bend refer to figure 5 Figure 6 Important Note Please do not crush or kink SteelFlex ducting as it will reduce air flow and may cause noise to occur through the system Ducting needs to be kept taut at all times Figure 5 90 degree curve PVC or galvanise curve 250mm flexible ducting DO NOT reduce ducting size ...

Page 20: ... over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual Support of the ducting with the use of hangers may be required see option 2 NOTE Ducting should be kept taut at all times Figure 7 Examples of securing ducting Option 1 Secure the SteelFlex duct to the beam Option 2 Support SteelFlex duct by using hangers NOTE Care shall be taken to minimize ...

Page 21: ...Page 21 7 Parts List Parts List for Isodrive 3200 14 3 16 21 15 1 17 18 10 19 20 12 11 4 Figure 8 1 3 4 11 12 14 15 16 17 18 10 19 20 21 ...

Page 22: ...1 M5X8 SUS Hex Nut Cap 4 14 P2003 Fan Guard 1 15 P1124 M4X12 Hex Washer Head S S ST 22 16 P2007 Fan Bottom Spinning 1 17 P2004 3200 Inlet Cone 1 18 P2005 Pipe Bracket 4 19 P1125 M4X14 Pan Head S S TT 4 20 P2006 250mm PVC Pipe 1 21 P301 Power Cable 1 22 P2020 M5X16 Hex Head Machine Screw 4 23 P2023 Cable Protective Grommet 200mm 1 P2025 Optional Wall Cover Plate Optional Back Draft Stopper Optional...

Page 23: ...r cleaning please completely cover the outside motor system and avoid all chemical contact IMPORTANT Any damages caused by the use of chemical products are not covered by warranty Figure 9 Avoid chemical contact to motor system Images for illustration purposes only Applies for all motors ...

Page 24: ...mer Under our policy of continuous product development product specifications may change without notice Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be lia...

Page 25: ...Page 25 Notes ...

Page 26: ...Page 26 Notes ...

Page 27: ...Page 27 Notes ...

Page 28: ...Drive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson com Web www parex co nz ...

Reviews: