Page 14
7. Installation
DANGER
Always switch off and disconnect power before installing the rangehood. Failure to
do so may cause serious injury.
Wall Mount Installation
Every wall mounted rangehood has two primary mounting
points and several secondary mounting points to firmly fix the
rangehood in its place.
Use suitable bolts to mount the appliance on a secure surface.
Please ensure that the holes for the two primary mounting
points are level before installation.
DANGER
Always switch off and disconnect power before
installing the rangehood. Failure to do so may
cause serious injury.
Primary mounting points
Secondary mounting point
may differ
*IMPORTANT: Please check all State and Federal Laws in relation to the minimum - maximum
heights, regulations concerning the expelling of air and install your rangehood in accordance
with local laws and regulations.
Mounting Laws and Regulations
The minimum distance between the bench top and the lowest part of the rangehood should not be
less than:
For indoor kitchen area:
The minimum safety installation distance between the top of a cooktop and the lowest part of the
rangehood are as follows:
Minimum installation height for electric and gas cooktops is 650mm*.
For rangehoods 90cm wide or larger:
Distances above 800mm can compromise the extraction
performance.
For 60cm wide rangehoods:
Distances above 750mm can compromise the extraction performance.
Suggested height above a Induction Cook top is 720mm to 800mm.
For more information please see
section Maintenance - Condensation Information*.
The location of the installation must have permanent openings for ventilation.
Regulations concerning the expelling of air have to be fulfilled.
It is strongly recommended that the rangehood be installed centrally over the cooktop.