Page 20
8. Maintenance
Troubleshooting
If the product does not work:
Before you contact the technical service department, make sure that the product is plugged in,
the electric fuse (on selected models) is in correctly and electric wiring is connected. (Fuses can be
purchased from your local electrical dealer or hardware store). Weak air suction may be caused by
back draft fins remaining closed. Do not take any action that will damage the product.
Technical Specifications
Model
WM2190-6S
Feeding Voltage
220-240V 50Hz
Lamp Power — Halogen (W)
2 x 35W (supplied)
Lamp Power — LED (W)
2 x 1.4-7W (optional)
Check electric connection. Voltage of the electric network should be between 220 - 240V, rangehood should be connected to grounded plug and turned on.
Check motor switch. Please ensure that there is power to the rangehood and the rangehood is switched on.
Check lamp switch. Lamp switch should be at on position.
Check metal filter. Metal filter should be washed regularly, see filter cleaning.
Check lamps. Lamps should be firm.
Check outlet. Outlet should be open.
Check lamps and fuse. Make sure they are not broken or faulty.
Please make sure there is no obstruction
in ducting or back draft fins.
Check the outlet, make sure it is not
blocked and you have the correct
diameter ducting installed.
Check Isodrive installation manual, make
sure the flexi ducting is installed correctly,
eg. Length of ducting used, keep the
ducting taut.
Rangehood does not work
X
X
Light does not work
X
X
X
X
Rangehood air suction is weak
X
X
X
X
Rangehood does not direct air out
(through chimney)
X
X
Loud noise from the rangehood
X
X