SEL-3022 Transceiver
Instruction Manual
Date Code 20050615
Introduction & Specifications
Specifications
1.12
Cryptographic Manual—Do Not Copy
Specifications
Indicators
Green LED:
Device Status
Solid-State Output
100 mA continuous
250 Vdc or 120 Vac Operational Voltage
Max. On Resistance: 50
Ω
Min. Off Resistance: 10 M
Ω
Insulation:
1500 Vdc
Wiring size:
14 AWG Max.
26 AWG Min.
0.4 mm Min. Insulation
105
°
C
, 250
V Min.
Encryption Protocols
AES:
128-bit encryption
Serial Port
Connectors:
DB-9 Female (DCE)
Data Rate:
300 bps to 38400 bps
Interface:
EIA-232
WiFi/802.11b Configuration Port
Protocol:
IEEE 802.11b
Modulation:
DSSS
Frequency Band:
2.4 GHz
Encryption:
128-bit WEP and
128-bit AES
Authentication:
HMAC SHA-1
128-bit key
External Antenna:
Reverse Polarity
Connector:
SMA Jack
Power Requirements
+5 to +24 Vdc:
<5 W
supplied through compression terminals or a
2.5 mm jack
Operating Temperature Range
–40
°
to +85
°
C (–40
°
to +185
°
F)
5 to 95% humidity (noncondensing)
Dimensions
3.675" wide
4.8" deep
1" high, without DIN mount
Type Tests
Electromagnetic Compatibility
Radiated Emissions: IEC 60255-25:2000,
Class A
FCC part 15 Class A
Electromagnetic Compatibility Immunity
Conducted
RF Immunity:
ENV 50141:1993,
10 V rms
IEC 61000-4-6:1996,
10 V rms
Digital Radio
Telephone RF:
ENV 50204:1995,
10 V/m at 900 MHz
and 1.89 GHz
Electrostatic
Discharge:
IEC 60255-22-2:1996,
IEC 61000-4-2:1999,
[EN 61000-4-2-1995],
Levels 1, 2, 3, 4
Fast Transient
Disturbance:
IEC 61000-4-4:1995,
IEC 60255-22-4:1992,
4 kV at 2.5 and 5 kHz
Radiated Radio
Frequency:
ENV 50140-1993,
IEC 60255-22-3:1989,
10 V/m
IEEE C37.90.2-1995,
35 V/m
Type Test Compliance Criteria:
1) The SEL-3022 does not damage or impede
IED operation.
2) The SEL-3022 is allowed to lose data
during testing events.
3) The SEL-3022 must recover without
external intervention.
Environmental
Cold:
IEC 60068-2-1:1990
[EN 60068-2-1-1993],
Test Ad: 16 hrs
@ –40
°
C
Dry Heat:
IEC 60068-2-2:1974
[EN 60068-2-2-1993],
Test Bd: 16 hrs @
+85
°
C
Damp Heat, Cyclic:
IEC 60068-2-30:1980,
Test Db: +25° to
+55°C,
6 cycles, 95% humidity
Vibration:
IEC 60255-21-1:1988,
Class 1
IEC 60255-21-2:1988,
Class 1
IEC 60255-21-3:1993,
Class 2
Max. Altitude:
2000 m
Preliminary Copy
Summary of Contents for SEL-3022
Page 6: ...This page intentionally left blank Preliminary Copy ...
Page 12: ...This page intentionally left blank Preliminary Copy ...
Page 26: ...This page intentionally left blank Preliminary Copy ...
Page 42: ...This page intentionally left blank Preliminary Copy ...
Page 102: ...This page intentionally left blank Preliminary Copy ...
Page 104: ...This page intentionally left blank Preliminary Copy ...
Page 105: ...Preliminary Copy ...