A.14
SEL-700G Relay
Instruction Manual
Date Code 20170814
Firmware and Manual Versions
Instruction Manual
Appendix H
➤
Updated Table H.2: Synchrophasor Order in Data Stream (Voltage and Currents).
Appendix I
Updated the setting description for the RBADPU setting prompt in Table I.5: M
IRRORED
B
ITS
Protocol Settings.
Appendix J
➤
Updated Overview.
➤
Updated Table J.1: SEL-700G Relay Word Bits and Table J.3: Relay Word Bit Definitions for the SEL-700G.
➤
Added Table J.2: Hidden Overcurrent Element Relay Word Bits Per the SEL-700G Model.
Appendix K
➤
Updated for rms data determination.
20150123
Preface
➤
Added Safety Information and General Information.
➤
Updated the product labels and compliance label.
Section 1
➤
Changed the Certifications section title to Compliance and relocated the section to the beginning of the
Specifications.
➤
Updated the Type Test compliance specifications in the Specifications.
20140806
Section 1
➤
Updated the entries for the 50N element in Table 1.2: Protection Elements in SEL-700G Models.
➤
Updated Specifications including Synchrophasor Accuracy.
Section 2
➤
Updated Card Configuration Procedure.
➤
Added a note stating that the fail-safe option should not be used for fast hybrid output contacts in fail-safe/
nonfail-safe tripping.
Section 4
➤
Updated Figure 4.14: REF Protection Output (Extremely Inverse-Time O/C), Figure 4.110: Simplified Block
Diagram, Frequency and Phase Matching, and Figure 4.111: Simplified Block Diagram, Voltage Matching
Elements.
➤
Added Figure 4.20: Phase-to-Phase Distance Element Operating Characteristics.
➤
Revised the text for the 25C element. The relay asserts the 25C Relay Word bit to initiate a close when the
angle difference equals the CANGLE setting. 25C assertion is timed so that, if the slip remains constant and
the breaker closes in TCLOSDX ms, the breaker main contacts close the instant the angle difference is equal
to CANGLE.
Section 5
➤
Updated the number of time-stamp entries that relay memory can hold for load profiling.
Settings Sheets
➤
Added notes for Port settings.
➤
Added Table SET.1: Port Number Settings Must be Unique.
Section 10
➤
Updated Table 10.9: Relay Self-Tests.
Appendix A
➤
Updated for firmware version R107.
Appendix B
➤
Added a note to save the calibration settings before the upgrade in Upgrade Firmware Using a Terminal
Emulator.
Appendix D
➤
Updated Table D.9: SEL-700G DNP Object List.
➤
Updated Table D.11: DNP3 Default Data Map.
Table A.5
Instruction Manual Revision History
(Sheet 5 of 8)
Revision Date
Summary of Revisions
Summary of Contents for SEL-700G Series
Page 14: ...This page intentionally left blank ...
Page 22: ...This page intentionally left blank ...
Page 32: ...This page intentionally left blank ...
Page 52: ...This page intentionally left blank ...
Page 106: ...This page intentionally left blank ...
Page 510: ...This page intentionally left blank ...
Page 560: ...This page intentionally left blank ...
Page 578: ...This page intentionally left blank ...
Page 588: ...This page intentionally left blank ...
Page 604: ...This page intentionally left blank ...
Page 634: ...This page intentionally left blank ...
Page 738: ...This page intentionally left blank ...
Page 802: ...This page intentionally left blank ...