39
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
Console Display
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact your local
distributor for further assistancee.
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
HR cable box connection
Be sure cables from handlebars and cable to Console are secure
and undamaged.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be kept
still with relatively equal pressure applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream (heart rate cream) can help make
better conduct. These are available on the web or at medical or
some larger fitness stores.
Static Handlebar
If tests reveal no other issues, Static Handlebar should be re
-
placed.
Unit operates but Telemet
-
ric HR not displayed
Chest Strap (optional)
Strap should be “POLAR
®
” compatible and uncoded. Make sure
strap is directly against skin and contact area is wet.
Interference
Try moving unit away from sources of interference (TV, Micro
-
wave, etc).
Replace Chest Strap
If interference is eliminated and HR does not function, replace
strap.
Replace Console
If HR still does not function, replace Console.
Unit operates but Telemet
-
ric HR displayed incorrectly
Interference
Make sure that the HR receiver is not blocked by a personal
electronic device in the left side of the media tray.
Console displays “E2” error
code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Console Electronics
If tests reveal no other issues, contact your local distributor for
further assistance.
troubleSHootIng
Summary of Contents for 270i Recumbent Bike
Page 10: ...10 3 Attach Seat Pads to Seat Frame Assembly 3 6 X8 4mm B E G H X4 2 G I...
Page 11: ...11 4 Attach Cover to Frame Assembly 4 7 5 Attach Seat Adjustment Handle to Frame Assembly...
Page 15: ...15 10 Attach Water Bottle Holder to Frame Assembly 2 X2 F 2...
Page 37: ...37 Maintenance Parts CC BB A AA Z Y D F B C E H I J K L M W X N V P O Q R T S U G...
Page 41: ...41...
Page 42: ...Nautilus Bowflex Schwinn Fitness Universal 8003249 090113 A EN...