Chapter 3 Configuring the XDQA24 System
To Change the General Configuration Settings
The following procedure explains how to change the general configuration settings of
the XDQA24.
1
On the web browser user interface of the XDQA24 system, click on the Device
link.
Result: The Device page is displayed.
2
In the QAM Encoding Type drop down box, select ITU-A, ITU-B, or ITU-C and
press the Apply command button.
Result: The settings of the XDQA24 system are replaced by the factory settings.
3
In the Device name box, enter a name for the XDQA system.
4
In the Device location box enter the location for the XDQA system.
5
In the Enabled drop down, select Yes to enable the Keep Alive feature or No do
disable this feature.
6
In the Repetition Rate box, enter the time between two successive Keep Alive IP
packet broadcasts.
7
In the PSI Settings table, enter the playout rate for the PAT in the Pate Rate box
and for the PMT in the PMT Rate box.
8
In the Stream Configuration table, select VBR or CBR in the Stream Mode SPTS
drop down box and Static or Dynamic in the Stream Mode MPTS drop down box.
9
Click on the Apply command button to confirm or the Reload command button
to abort the operation.
22
4018055 Rev B
Summary of Contents for Continuum DVP eXtra Dense QAM Array 24
Page 1: ...4018055 Rev B Continuum DVP eXtra Dense QAM Array 24 Configuration Guide...
Page 2: ......
Page 4: ...For Your Safety iv 4018055 Rev B...
Page 6: ......
Page 10: ......
Page 12: ......
Page 14: ......
Page 24: ......
Page 32: ......
Page 44: ...Chapter 3 Configuring the XDQA24 System 30 4018055 Rev B...
Page 64: ......
Page 88: ......
Page 96: ......
Page 103: ......