background image

15

User Manual PSD3005

Notes

Summary of Contents for PSD3005

Page 1: ...User Manual 30 V 5 A Power Supply PSD3005 ...

Page 2: ...instrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding previous released material Scientific continues to improve products and reserves rights to amend part or all of the specifications procedures equipment at any time without notice Rev 1 2 0414 2 User M...

Page 3: ...ont Panel ontrols 4 Operating Instructions 8 General Information 8 Safety 8 Operating Conditions 8 First Time Operation 9 Operation 9 6 Maintenance 11 Power Line Fuse Replacement 11 7 Dispatch Procedure for 12 Service 12 8 Warranty Conditions 13 9 List of Service Centers C 6 14 3 User Manual PSD3005 ...

Page 4: ... provides floated DC output voltage and is ideally suitable for complexAnalog and Digital testing The DC output can be continuously adjusted from 0 to 30 V with coarse and fine controls Current limit is also adjustable from 0 5 A Any over loading for adjusted current limit is indicated by A LED When the maximum setting is crossed or the overheating has occurred the LED will lit A dual 3 digit disp...

Page 5: ...ly variable by means of coarse and fine controls 5 A Max Voltage 10 mV Current 5 mA 10 m 2 5 mV at 30 V 5 A 50 s 0 05 10 mV 0 05 10 mV 0 05 10 mV C 1 mVrms Adjustable between 500 mA to 5 A 3 digit for voltage and current 1 1digit By litting A LED Built in overheat overvoltage overload protection Between chassis and output 10 M at 100 V dc Between chassis and AC plug 50 M at 500 V dc 230 V 10 50 60...

Page 6: ...Front Panel Controls 6 User Manual PSD3005 30 0 V 3 00 FINE Iset COARSE POWER ON OFF 5 00 30 0 A V 1 2 3 4 6 5 30V 5A POWER SUPPLY PSD3005 30V 5A ...

Page 7: ...ly is in constant current mode VARIABLE POTENTIOMETER VARIABLE POTENTIOMETER VARIABLE POTENTIOMETER NOTE The instrument is provided with over voltage protection from mains variation The mains input voltage is selected by switch on back side If the voltage exceeds 240 V mains it is recommended to select the 240 V tapping The over voltage setting for safe operation is set at approx 270 V for mains i...

Page 8: ...ction must not be negated by the use of an extension cord without a protective conductor When removing the metal case or replacing the instrument must be completely disconnected from the mains supply If any measurement or calibration procedures are unavoidable on the opened up instrument these must only be carried out by qualified personnel acquainted with the danger involved The ambient temperatu...

Page 9: ...ndue observation should be noticed Once the instrument is switched ON the power ON is indicated by liting of displays The power supply has an electrically floating output This permits easy series or parallel connection with other power supply units to increase supply voltage or current respectively 9 User Manual PSD3005 Circuit under Test 30 0 V 3 00 FINE Imax COARSE POWER ON OFF A V 30V 5A POWER ...

Page 10: ...on The over voltage setting is at 253 V whenever the mains increases beyond the set voltage it trips and LED is lit After the mains normalized switch OFF once the instrument and then switch ON again if the mains is below 253 V the instrument get switched ON other wise trips again 10 User Manual PSD3005 ...

Page 11: ...es the cleaning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instrument does not show any sign of working no LED is lit or there is no display immediately switch OFF the mains power switch of the instrument and unplug the mains cord from the mains socket With the he...

Page 12: ... noticed 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is possible in your premises 2 Dispatch the instrument only on the receipt of our advise securely packed in original packing duly insured and freight paid along with accessories and a copy of the faults details noticed at our ...

Page 13: ... damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LCD fuses batteries or accessories This warranty is only valid with the original purchaser who must have properly registered the product within 15 days from date of purchase No other warranty is expressed or implied 4 When it becomes necessary to retur...

Page 14: ...14 User Manual PSD3005 Notes ...

Page 15: ...15 User Manual PSD3005 Notes ...

Page 16: ...t chennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia com Co op Hsg Society Ltd Senapati Bapat Marg Dadar W Mumbai 400 028 Scientific Mes Technik Pvt Ltd Ph 020 26114688 209 Lloyd s Chamber III Fax 020 26132882 409 Mangalwar Peth pune scientificindia co...

Reviews: