background image

16

User Manual PSD3205

Scientific Mes-Technik Pvt. Ltd.,

Ph : (0731) 2309741,2422330-31

92, Electronics Complex,

Fax :(0731)2422334, 2561641

Pardeshipura,

info@scientificindia.com

Indore M. P. 452 010

Scientific Mes-Technik Pvt. Ltd.,

Ph : (011) 65638100, 65638101

B-13, D.S.I.D.C Packging Complex

Fax:(011)26536298

Kirti Nagar, New DelhiI 110 015

ndelhi@scientificindia.com

Scientific Mes-Technik Pvt. Ltd.,

Ph : (080) 23437635

NO. 46, 4th Main Cross ,

Fax:(080)23331478

MLA Layout,

bangalore@scientificindia.com

R. T. Nagar, Bangaluru 560 032

Scientific Mes-Technik Pvt. Ltd.,

Ph : (044) 24424598

No. 25 , 2 nd floor,

Fax :(044) 24420421

29 th Cross Street

chennai@scientificindia.com

Indira Nagar, Adyar
Chennai

600 020

Scientific Mes-Technik Pvt. Ltd.,

Ph. :(022) 24211171

Room No. 308, Building No.2,

Fax :(022)24333654

3rd Floor, Sundar Nagar

mumbai@scientificindia.com

Co-op. Hsg Society Ltd.
Senapati Bapat Marg, Dadar (W)
Mumbai 400 028

Scientific Mes-Technik Pvt. Ltd.,

Ph. : (020)26114688

209, Lloyd

s Chamber III

Fax : (020)26132882

409, Mangalwar Peth,

pune@scientificindia.com

Maldhakka Chowk ,
Pune 411 011

Scientific Mes-Technik Pvt. Ltd.,

Scientific Mes-Technik Pvt. Ltd.,

Major Service Centers

Phone / Fax / Email

Ph : (040)27534995

"Krupa Ashirwad Complex",

Fax : (040)27534996

2nd Floor, Door No.5-2-394 81/A,

hyderabad@scientificindia.com

R.P. Road, Hyderbasti
Secunderabad 500026

Ph : (033) 2228 2223-6

2, Chowringhee Road,

Fax : (033)2228 1713

Kolkata 700 013

kolkata@scientificindia.com

1.

2.

3.

4.

5.

6.

7.

8.

Summary of Contents for PSD3205

Page 1: ...User Manual Dual Display Tracking Multiple Power Supply 3205 PSD...

Page 2: ...nstrument contains proprietary information no part of this manual may be photocopied reproduced or translated without any prior written consent Information in this manual supercede all corresponding p...

Page 3: ...tions 5 3 Front Panel ontrols 4 Operating Instructions 8 General Information 8 Safety 8 Operating Conditions 8 First Time Operation 9 Operation 9 6 Maintenance 12 Power Line Fuse Replacement 12 7 Disp...

Page 4: ...as a constant current CC and constant voltage CV source for laboratories industries field testing applications featuring low power loss compact and light weight It provides isolated floated adjustabl...

Page 5: ...0 30 V 3A B 0 30 V 3A 0 30 V continuously variable by means of coarse fine controls 3 A Max Voltage 10 mV Current 5 mA 10 m 2 5 mV at 30 V 3A 50 s 0 05 10 mV 0 05 10 mV 0 05 5mV C 1 mVrms 1 Adjustabl...

Page 6: ...1 Front Panel Controls 6 User Manual PSD3205 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF 3 00 A V TRACK 1 2 3 4 5 6 7 8 9 11 10 A 30V 3A B 30V 3A TRACK DUAL DISPLAY TRACKING POWER SUPPL...

Page 7: ...hat the supplyAis in constant current mode Similarly LED B will lit B is in constant current mode When theTRACK mode is selectedTK LED will lit The instrument is provided with over voltage protection...

Page 8: ...tion must not be negated by the use of an extension cord without a protective conductor When removing the metal case or replacing the instrument must be completely disconnected from the mains supply I...

Page 9: ...ns supply 230 V 10 On switch ON no undue observation should be noticed Once the instrument is switched ON the power ON is indicated by liting of displays The power supply has an electrically floating...

Page 10: ...h shorting clamps connections are done as per above diagram In this mode t he supplyAact as a Master unit B as Slave unit Circuit under Test 30 0 V 3 00 COARSE FINE Imax COARSE FINE Imax POWER ON OFF...

Page 11: ...eeds 240 V AC it is recommended to select 240 V tapping The over voltage setting for safe operation is set at approx 270 V for mains input voltage when the tapping is set to 240 V Whenever the mains i...

Page 12: ...aning fluid should get into the instrument The use of cleaning agents can attack the plastic paint surfaces The power line fuse is located on rear panel on lower right side In case the instrument does...

Page 13: ...l details of the fault noticed 1 After receipt of your communication our service department will advise you whether it is necessary to send the instrument back to us for repairs or the adjustment is p...

Page 14: ...any defect failure or damage caused by accident negligence mis application alteration or attempt to repair service or modify in any way 3 This warranty does not include LED fuses batteries or accesso...

Page 15: ...15 User Manual PSD3205 Notes...

Page 16: ...chennai scientificindia com Indira Nagar Adyar Chennai 600 020 Scientific Mes Technik Pvt Ltd Ph 022 24211171 Room No 308 Building No 2 Fax 022 24333654 3rd Floor Sundar Nagar mumbai scientificindia...

Reviews: