1. Safety Instructions

Warning!

Read the operating instructions carefully

before use.

Ensure that only trained staff works with the

instrument.

Risk of burn!

Caution when touch the housing parts and

the  hotplate which can reach temperature of

280°C.

Pay attention to the residual heat after

switching off.

Protective ground contact

ʽ

Make sure that socket must be grounded

(protective ground contact) before use.

• When work

ing wear personal safety guards to avoid the

risk from:

- Splashing and evaporation of liquids

- Release of toxic or combustible gases

• Set up the instrument in 

a spacious are on a stable, clean,

non-slip, dry and fireproof surface. Do not operate the

instrument in explosive atmospheres, with hazardous

substances or under water. 

• Gradually increase the speed, reduce the speed 

if:

- Stirring bar breaks away due to high speed

- The instrument is not running smoothly, or container

moves on the base plate 

• Te

mperature must always be set at least 50

ć

 lower than

the fire point of the media used.

• Be

 aware of hazards due to:

- Flammable materials or media with a low boiling

temperature 

- Overfilling of media

- Unsafe container

• Process pathogenic materials only in closed vessels.
• Check the instrume

nt and accessories prior to each use.

Do not use damaged components. Safe operation is only

guaranteed with the accessories described in the

Accessories

” 

chapter. Accessories must be securely

attached to the device and can not come off by themselves.

Always disconnect the plug before fitting accessories.

When the external temperature sensor needed, the tip of

the measuring sensor must be at least 5-10mm from vessel

bottom and wall.

Summary of Contents for 861520039999

Page 1: ...LED Digital Magnetic Stirrer SCI280 Pro SCI PA SCI PB Classic Magnetic Stirrer Please read the User Manual carefully before use and follow all operating and safety instructions Technical specificatio...

Page 2: ...ems 4 4 Control 4 4 1 Control elements 4 4 2 Display 7 5 Trial Run 8 6 Function Heating Digital hotplate model 8 6 1 Working with external temperature sensor 9 6 2 Residual heat warning HOT 9 7 Stirri...

Page 3: ...e Methods and procedures adopted to resolve the problems Your contact information Warranty This instrument is warranted to be free from defects in materials and workmanship under normal use and servic...

Page 4: ...substances or under water Gradually increase the speed reduce the speed if Stirring bar breaks away due to high speed The instrument is not running smoothly or container moves on the base plate Tempe...

Page 5: ...ate Do not cover the device The instrument may only be opened by experts Keep away from high magnetic field 2 Proper Use The instrument is designed for mixing and or heating liquids in schools laborat...

Page 6: ...nical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The package includes the following items Items Qty Main unit 1 Power cab...

Page 7: ...5 Speed Control Knob LED Display Figure 3 Digital model Speed Control Knob Figure 4 Classic model Figure 5...

Page 8: ...all settings Probe When the external temperature sensor PT1000 is plugged in probe icon is lit Power Switch Switch ON or OFF the instrument Digital model Temperature Control Knob Stir Set the rotary...

Page 9: ...temperature is still above 50 C LED displays Hot otherwise LED displays OFF Speed display area When stirring function was switched ON LED displays the speed setting value and flashes The setting valu...

Page 10: ...ating Digital hotplate model The device is controlled by digital temperature control technology which has two separate safe circuits The hotplate is kept at a constant temperature by a digital control...

Page 11: ...conditions Please operate follow the instructions below Switch OFF the instrument Ensure the external temperature sensor is inserted in the media heated Switch ON the instrument and run heating funct...

Page 12: ...ether the power line is unplugged Check whether the fuse is broken or loose Fault in power on self test Switch OFF the unit then switch ON and reset the instruments to factory default setting Stir spe...

Page 13: ...s method will not harm the instrument Wear the proper protective gloves during cleaning of the instrument Note Electronic device can not clean with cleanser If you require maintenance service must be...

Page 14: ...quency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely...

Page 15: ...Temperature display accuracy C 1 The safe temperature of hotplate 320 Temperature sensor in medium PT1000 Control accuracy of heating temperature with temperature sensor f0 5 Items Specifications Digi...

Page 16: ...017777 SCI280 Pro BlueSpin Double LED Digital Hotplate Magnetic Stirrer stainless steel with corrosion resistant coated hotplate USA plug 100 120V 50Hz 60Hz 861131127777 SCI280 Pro BlueSpin Double LED...

Page 17: ...ssories 18900016 PT1000 A Temperature sensor for digital hotplate model length 230mm 18900136 PT1000 B Temperature sensor with glass coated 230mm 18900148 Support clamp of PT1000 18900080 Reaction blo...

Page 18: ...SCILOGEX LLC 1275 Cromwell Avenue Suite C6 Rocky Hill CT 06067 USA Office 1 860 436 9221 Sales Service contact info scilogex com www scilogex com...

Reviews: