13. Ordering information   

Cat. No. 

Model 

Descriptions 

912015137777 

DM0636 

Multi-purpose  Centrifuge

with  SE4-100  rotor  kits,  US  plug, 

110V/50Hz/60Hz 

91211517777 

DM0636 

Multi-purpose Centrifuge

with SE4-100 rotor kits,    Cn plug, 

220V/50Hz/60Hz 

912215127777 

DM0636 

Multi-purpose Centrifuge

with SE4-100 rotor kits, Euro plug , 

220V/50Hz/60Hz 

912315127777 

DM0636 

Multi-purpose  Centrifuge

with  SE4-100  rotor  kits,  UK  plug, 

220V/50Hz/60Hz   

Accessories 

19400002 

AS30-2 

Rotor kits with cover, fixing clips and O'ring, 6000rpm, 

2ml*30, used with D1536 & D1536R 

19400002 

AS18-5V 

Rotor kits with cover, fixing clips and O'ring, 6000rpm, 

5mlV*18, used with D1536 & D1536R 

19400003 

AS60-2 

Rotor kits with cover, fixing clips and O'ring, 6000rpm, 

2ml*60, used with D1536 & D1536R 

19400002 

AS12-PCR8 

Rotor kits with cover, fixing clips and O'ring, 6000rpm, 

PCR8*12, used with D1536 & D1536R 

19400002 

AS6—50V 

Rotor kits with cover, fixing clips and O'ring, 6000rpm, 

50mlV*6, used with D1536 & D1536R 

19400002 

A30-15 

30-

Φ

17stainless tubes, 4500rpm, 30-15mlV tubes, used with 

D1536 & D1536R 

19400004 

A8-50 

16-

Φ

17stainless tubes and 8-

Φ

31stainless tubes, 5000rpm,   

16-15mlV tubes and 8-50mlV tubes, used with D1536 & 

D1536R 

19400004 

SE4-100A 

4-

Φ

45stainless tubes and 4-

45 

stainless rings, 4000rpm,   

4-100ml tubes, used with D1536 & D1536R 

19400004 

S2-MP 

2-

bucket

s and 2-

stainless carrier

, 4000rpm, used with 

D1536 & D1536R 

 

A85P100 

85ml rotor adapter, used with SE4-100 rotors, 4pcs/pk 

 

A50VP100 

50mlV rotor adapter, used with SE4-100 rotors, 4pcs/pk 

 

A15VP100 

15mlV rotor adapter, used with SE4-100 rotors, 4pcs/pk 

 

A10P100 

3

10ml rotor adapter, used with SE4-100 rotors, 4pcs/pk 

19500001 

A02P2 

0.2ml rotor adapter, used with AS30-2 & AS60-2 rotors

30pcs/pk 

19500002 

A05P2 

0.5ml rotor adapter, used with AS30-2 & AS60-2 rotors, 

Summary of Contents for DM0636

Page 1: ...DM0636 Multi purpose Centrifuge Before using centrifuge please carefully read this user manual for its efficient operation and safety...

Page 2: ...ect the rotor 8 7 5 Symmetrically load centrifuge tubes in rotor 8 8 Operation 8 8 1 Normal Operation 8 8 2 RCF Operation 12 8 3 Pulse Operation 12 9 Maintenance 12 9 1 Cleaning 12 9 2 Consumables 13...

Page 3: ...USER MANUAL 2...

Page 4: ......

Page 5: ...y be reproduced or transmitted without prior written permission of original manufacture We can not be responsible to inform at real time if the outline and specifications of centrifuge is subject to c...

Page 6: ...death CAUTION Possible damage to instrument Caution notes indicate any condition or practice which if not strictly observed or remedied could result in damage or destruction of the instrument NOTE Not...

Page 7: ...orizontal before running Make sure the angle between the door and cover is greater than 70 degrees when open the door Be careful not put your fingers or hands between the door and cover when the door...

Page 8: ...emperature detector Imbalance protection Automatic internal diagnosis Power requirements Single phase 220V 240V 50Hz 60Hz 8A 110V 120V 50Hz 60Hz 12A Dimensions mm L 280 W 364 H 266 Weight 30kg Additio...

Page 9: ...ich case the user will be required to correct the interference 3 Required Operational Condition 3 1 Basic operational Conditions 1 Power Single phase 220V 240V 50Hz 60Hz 8A Single phase 110V 120V 50Hz...

Page 10: ...at least 30cm behind it to guarantee the cooling efficiency 4 Keep away from heat or water to avoid sample temperature issues or centrifuge failures 4 2 Connection of the power cord and grounding WAR...

Page 11: ...Open lock key Press the key to open the door The key is not available when the centrifuge is running 3 Start Stop key Press the key to start running The centrifuge will brake to stop running if press...

Page 12: ...is 9 memory program is 7 When speed symbol is rotating indicating the centrifuge is running the rotation is faster the speed is higher Temperature only displays the temperature of chamber and can not...

Page 13: ...erwise the rotor may be moved off while rotating and cause damage of the centrifuge and rotor Firmly tighten the rotor door with rotor 8 Operation CAUTION Do not push or lean against the centrifuge wh...

Page 14: ...00rpm Running time 30 minutes The door lock is released 8 1 1 Load and replace the rotor Figure 8 2 Load the rotor CAUTION Attach the rotor to the rotor shaft Ensure the rotor is in position and conne...

Page 15: ...peed symbol will flash the speed value The minimum speed value you can set 300rpm the minimum increment is 100rpm Rotate parameter key clockwise to increase speed value rotate the parameter key anti c...

Page 16: ...normal operation mode and run according to the new value If the set time value has been modified the operation time is not affected and will continue 3 Warning display If an error occurs during the o...

Page 17: ...the power switch and load the rotor to the shaft tighten the rotor lid and make sure it is in secured position and then close the door 2 The centrifuge gets into preparation mode and displays last ru...

Page 18: ...mple leaks in the rotor rinse the rotor with water Apply a thin coat of silicon grease to the rotor when it is completely dry The rotor should be regular maintenance recommend to cleaning it each 3 mo...

Page 19: ...n the table firmly 2 Check if the centrifuge grounded properly Use multi meter to check if is short circuit between the power cord grounding pin and the motor shaft If yes indicating grounded properly...

Page 20: ...llowable imbalance is exceeded some wrong in the drive system Balance the sample checked by professional person E 10 86 Read the service manual Contact with service center Table 10 1 Possible problems...

Page 21: ...eed the allowable maximum speed of rotor tube and adapters etc be care that the allowable maximum speed of some adapters are lower than the rotor s maximum speed 11 1 The rotor instructions 11 1 1 Rot...

Page 22: ...50mlV 4 A50VP100 4000 15 9 2840 15mlV 8 A15VP100 4000 15 1 2700 3 10ml 8 A10P100 4000 14 7 2630 9 S2 MP dimension mm MTP 128 85 6 15 4000 12 1 2160 Cell culture 128 85 6 21 4000 12 1 2160 DWP 128 85 6...

Page 23: ...5 Bio safe seal ring The rotor is sealed by bio safe structures achieved using three high temperature rubber seal rings The seal rings may fall off or aging after several autoclaving need to be repla...

Page 24: ...ove screw nuts and inner covers to prevent from deformation or rupture 3 Wait until the sterilizing chamber cools down to the room temperature before the tubes are removed 11 2 4 Condition and life ex...

Page 25: ...otor kits with cover fixing clips and O ring 6000rpm PCR8 12 used with D1536 D1536R 19400002 AS6 50V Rotor kits with cover fixing clips and O ring 6000rpm 50mlV 6 used with D1536 D1536R 19400002 A30 1...

Page 26: ...the following conditions even if within the guarantee period expires 1 Failures caused by incorrect installation 2 Failures caused by rough or improper handling 3 Failures caused by conveyance or rel...

Page 27: ...USER MANUAL 22 SCILOGEX LLC 1275 Cromwell Ave Suite C6 Rocky Hill CT 06067 United States Office 1 860 436 9221 Fax 1 860 436 9745 Sales service contact info scilogex com www scilogex com...

Reviews: