3 OF 6
C4. FLUIDS PERMITTED
• Chemical products: Urea, weak acid & weak alkaline fluid etc.
• Water
D. MOVING AND TRANSPORT
Given the limited weight and size of the pumps (see overall dimensions), moving the pumps is simple and
does not require the use of lifting devices.
E. INSTALLATION
E1. DISPOSING OF THE PACKING MATERIAL
The packing material does not require special precautions.
Refer to local regulations for disposal.
E2. PRELIMINARY INSPECTION
• Check that the pump has not suffered any damage during transport or storage.
• Clean the inlet and outlet openings, removing any dust or residual packing material.
• Make sure that the motor shaft turns freely.
• Check that the electrical specifications correspond to those shown on the identification plate.
ATTENTION!
THE MOTORS ARE NOT ANTI-EXPLOSIVE TYPE. Do not install them where inflammable vapours can
be present.
E3. CONNECTING THE TUBING
• Before connection, make sure that the tubing and the suction tank are free of dirt and thread residue that
could damage the pump and its accessories.
• Before connecting the delivery tube, partially fill the pump body with Adblue to facilitate priming.
• Do not use conical threaded joints that could damage the threaded pump openings if excessively tightened.
SUCTION TUBING:
- Minimum recommended nominal diameter: 3/4”
- Nominal recommended pressure: 10bar / 145psi
- Use tubing suitable for suction pressure
DELIVERY TUBING:
- Minimum recommended nominal diameter: 3/4”
- Nominal recommended pressure: 10bar/145psi
ATTENTION!
It is the installer’s responsibility to use tubing with adequate characteristics.
Loosening of the connections (threaded connections, flanging, gasket seals) can cause serious
safety issues.
Check all the connections after the initial installation and before each use.
Tighten the connections, if necessary.
PERMITTED