background image

2 OF 6 

 

  WARNING: Read carefully and understand all 

INSTRUCTIONS before operating. Failure to follow the safety 
rules and other basic safety precautions may result in serious 
personal injury. 

 

 

A. MACHINE DESCRIPTION 

PUMP:

 Self-priming, volumetric, diaphragm pump, equipped with internal by-pass valve. 

MOTOR:

 Asynchronous motor, single-phase, 2 pole, closed type (protection class IP55 in conformance with 

EN 60034-5-86 regulations) self-ventilated. 

 

B. TECHNICAL DATA 

B1. Configuration 

Item No. 

Pump model 

Voltage 

Suction Hose 

Delivery Hose 

Nozzle 

Flow Meter 

SAPK12V01 

SP12VADEF 

12V 

1.5M 

6M 

Manual 

N/A 

SAPK24V01 

SP24VADEF 

24V 

1.5M 

6M 

Manual 

N/A 

 

C. OPERATING CONDITIONS 

C1. ENVIRONMENTAL CONDITIONS 

TEMPERATURE

: Min. -10oC

1

4℉)

  / Max. +60oC(14

0℉)

 

RELATIVE HUMIDITY

: Max. 90% 

  ATTENTION! 

The temperature limits shown should be adhered to, to avoid damage to the pump. 

 

C2. ELECTRICAL POWER SUPPLY 

1.  During installation and maintenance, make sure that the electric supply lines are not live.   

2.  Always turn off the switch before supplying electrical power. 

3.  Check the correct rotation direction of the DC pump. If it is inverted, check the polarity of the connection 

cable. 

a)  RED cable: positive pole (+) 

b)  BLACK cable: negative pole (-) 

  ATTENTION! 

Power from lines with values outside the indicated limits can damage the electrical components. 

 

C3. WORKING CYCLE 

1. Extreme operating conditions with working cycles longer than 30 minutes can cause the motor temperature 

to rise, thus damaging the motor itself. 

2. Each 30-minute working cycle should always be followed by a 30-minute power-off cooling phase. 

3. MAXIMUM BY-PASSING TIME: 3 MINUTES. 

Reviews: