MANUTENZIONE
MAINTENANCE
7
DESCRIPTION
INSPECTION
INTERVALS
OPERATIONS
Conveyor belt R
Visual inspection
8 h
Clean with a vacuum
cleaner (para. 7.1)
Weekly
Clean with a solution of
water and alcohol (para. 7.6)
Yearly
Adjust (para. 7.6)
Tensioning and centering
400 h
If necessary, adjust
check
correctly the conveyor
belt (para. 5.10)
Conveyor belt
Outer visual check
40 h
Clean outer surfaces with
feeding unit B
a vacuum cleaner
Belt feeding reduction gear
Oil level check
200 h
If need be, fill with MR oil
(if not lifetime lubricated) C
(par. 7.8, 7.10)
Change oil
After the first 400 working
Drain the used oil and fill
hours and after:
with new MR oil up to the
- every 5.000 h (or 2 years) right level (para. 7.8, 7.10)
(mineral oil)
- every 18.000 h (or 4 years)
(synthetic oil)
Epicyclic speed variator
Oil level check
200 h
Fill with MV oil, if
of conveyor belt
necessary (para.7.8, 7.10)
(optional device) D
Change oil
After the first 200 working
Drain the used oil and fill
hours and then every 2.000 with new MV oil, up to the
h (or 1 year)
right level (para. 7.8, 7.10)
Working units S belts
Tensioning and wear
200 h
Tension properly or replace
check
whenever necessary
(Para. 7.11-9.6)
Belts O of brush-type cleaning
Tensioning and wear
800 h
Stretch them correctly
roller unit - Scotch polishing check
or replace them, if need be
roller unit (optional devices)
(Para.7.9 - 9.4)
Table lifting unit F
Outer visual inspection
40 h
Clean outer surfaces with
the vacuum cleaner
Table reduction gear G
Oil level control
200 h
If need be, fill with MR
(if not lifetime lubricated)
oil (para. 7.9, 7.10)
Change oil
After the first 600 h
Drain the used oil and fill
and then:
with new MR oil, up to
- every 8.000 h (or 3 years)
the right level (para. 7.9,
(mineral oil)
7.10)
- every 25.000 h (or 6 years)
(synthetic oil)
Table lifting unit chain H
Visual inspection
200 h
Clean with benzine and
lubricate with CTN oil
(Para. 7.10)
Stretching check
400 h
If need be, stretch the
chain correctly
(Para. 7.7)
Compressed air regulator Check bowl and filter
40 h
Drain the condensate
I
possibly present in the bowl
L and clean filter M
with benzine and a
compressed air jet
Automatic positioner
Precision check
1500 h (or 1 year)
Carry out a measuring
(optional device) N
test with a sample panel
(Para. 5.11)