SCR331-DI Product Technical Manual
4.5.6 Overview of Contact-less APDU Set
Memory card APDU Set
Command
CLA INS
P1
P2
P3
Data
ISO7816_READ_BINARY
0xFC
0xB0
Block No.
RFU
0x00
None
ISO7816_WRITE_BINARY 0xFC
0xD0
Block No.
RFU
Length
Lc bytes
ISO7816_VERIFY
0xFC
0x20
AUTH_KEY
RFU
Key Length Lc bytes
ISO7816_USER_CMD
0xFC
0xFE
RFU
RFU
Cmd Len
Cmd
ISO7816_VALUE_BLOCK
0xFC
0xF0
Block No.
Value-
Param
Value bytes Value, Block
No.
T=CL card APDU Set
Command
CLA INS
P1
P2
P3
Data
T=CL command
ISO 7816 part 4 complaint command
T=CL user command
0xFC
0xFE
RFU
RFU
Length
APDU bytes
T=CL GET IFSC command 0xFC
0xFD
RFU
RFU
0x00
None
The P1 field of the Read/Write Byte APDU contains the block number of Type A contact-less
memory cards.
The P1 field of the Verify Byte APDU contains the Key type like AUTHKEY_A, AUTHKEY_B of
Type A contact-less cards.
The P2 field of the ISO7816_VALUE_BLOCK Byte APDU contains Value parameters like Value
Increment, Value decrement.
IND.SCR331-DI.MANUAL.VER.1.8
VER1.8
Page 18 of 36