Scope DataPage UHF MK2 Radio Paging System
DPMK2/6
10
07/05
3: Phone
(refer also to Section 2: Telephone Interface
)
This section is only applicable to models: NDPDTMF, NDPLP
The telephone interface can be programmed through the keyboard as follows:
Press key 3. The screen will change to display:-
RINGS TO ANSWER:
>
1
Select a number in the range 1-9 and press ENTER. This will define the number of rings before the system
will pick up the line. Pressing CANCEL will abort the change and return you to the programming menu.
Note, this value refers to the NDPDTMF model only, as the NDPLP version does not ring, but merely picks
up the line.
After pressing ENTER, the display will change to:
INACT’V TIMEOUT:
>
10
(The number shown is just an example
)
Enter a number in the range 2-99 secs. This will adjust the inactivity time (i.e. no button presses) after which
the line will be dropped.
After pressing ENTER, the display will change to:
ANS TONE DELAY:
>
2
This number must fall within the range of 1-99 (each unit = 0.1 sec approx.). This will adjust the delay time
from the moment the line is picked up to the time that the sign on tones are generated.
4: Serial
This connection is reserved for advanced programming and for specialist applications.
It will not therefore be accessible to the user for systems supplied in the standard configuration.
Press key 4. This sets the serial data communication speed between the transcoder and host. The screen
will change to display:
BAUD RATE (1-8)
9600
Enter a number in the range 1-8. 1=300, 2=600, 3=1200, 4=2400, 5=4800, 6=9600, 7= 19200, 8=38400
baud.
After pressing ENTER, the display will change to:
PARITY (1-3):
NONE
Enter a key in the range 1-3. 1=None, 2=Odd, 3=Even.
After pressing ENTER, the display will change to:
DATA BITS (7-8):
Enter a number in the range 7-8 to set.
>
8