Testing of Observatory Operation
Note: After installation of all shutters, it is ABSOLUTELY NECESSARY to
open and close them in correct order using the manual control panel. An
incorrect order of their
opening and closing can damage the shutters or
their drives units.
The correct order of opening the covers is:
- Shutter #3
- Shutter #2
- Shutter #1
The correct order of closing them is:
- Shutter #1
- Shutter #2
- Shutter #3
The first attempt to OPEN and CLOSE the observatory shall be carried out slowly
and very carefully, verifying that the covers or their handles do not interfere with
the drive shafts in the opening or closing positions.
DURING OPENING
, it is also necessary to verify that the shutters do not touch each ot
her’s
edges and
make appropriate adjustments to the mounting in the handles if necessary
. This applies in particular
to the operation of opening Shutter #1, which in open position hides between the Shutter #3 and #2.
During the assembly of this observatory in the factory, all components have been verified and
properly adjusted. However, during the reassembly process there may be minor differences that will
require corrections at this testing stage.
Figure. 56
–
observatory with shutters installed in closed position