GE 2000 A.R.S.
2
WARNING! Read all instructions before operating the inflator
. Failure to follow all instructions listed below may result in
product damage, and/or serious injury.
SAVE THESE INSTRUCTIONS
WARNINGS:
1.
Read these instructions.
2.
Keep these instructions.
3.
Protect the cord and the Pressure-Sensor Hose from being walked on or pinched.
4.
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way.
5.
Do
n’t disassemble the product. Incorrect reassembly may result in a risk of Short Circuit.
6.
Keep this product out of the reach of children.
DO NOT SUPPLY THE INFLATOR AT HIGHER OR LOWER VOLTAGE THAN NOMINAL.
GENERAL SAFETY RULES
7.
CONSIDER WORK AREA ENVIRONMENT.
Donʼt expose the device to heavy rain. Donʼt use in presence of flammable liquids
or gases.
8.
DONʼT ABUSE CORD.
Never carry device by cord or yank it to disconnect from receptacle. Keep cord from heat, oil, and sharp
edges.
9.
STAY ALERT.
Watch what you are doing. Use common sense.
10.
CHECK DAMAGED PARTS.
Before further use of the device, a guard or other part that is damaged should be carefully checked
to determine that it will operate properly and perform its intended function.
11. DO NOT OPERATE
portable device near flammable liquids or in gaseous or explosive atmospheres.
12.
WARNING! RISK OF UNSAFE OPERATION.
Do not modify or attempt to repair. Never drill into or make any modifications to
the device or its attachments.
INTENDED USE
GE 2000 ARS is a system able to keep the nominal pressure inside a large inflatable structures within pre-set values (min. 50 mbar, max.
400 mbar), independently from ambient temperature. The unit constantly monitors the pressure variation inside the inflatable structure
and regulates the operation to ensure pressure top-up and pressure relief.
1.
The GE 2000 ARS (is a unit able to INFLATE, MAINTAIN A PRESET PRESSURE and DEFLATE a LARGE INFLATABLE
STRUCTURE. THAT MEANS THE UNIT MUST BE ALWAYS BE CONNECTED TO THE INFLATABLE.
2.
THE ARS IS DELIVERED WITH A FACTORY PRESSURE SET. IF THE SET PRESSURE NEEDS TO BE CHANGED,
PLEASE FOLLOW CAREFULLY THE INSTRUCTIONS CONTAINED IN THIS MANUAL. IN CASE OF DOUBTS PLEASE
CONTACT SCOPREGA.
3.
THE INFLATOR IS PROVIDED WITH HOSES AND ADAPTORS TO BE CONNECTED TO THE MOST COMMON
INFLATION VALVES
4.
THE INFLATOR IS FITTED WITH TERMAL OVERLOAD SWITCHES THAT WILL INTERVENE IN CASE OF
OVERHEATING. NORMAL OPERATION WILL RESUME AUTOMATICALLY AFTER A PAUSE OF 20/40 MINUTES