Page 69
TO TEST THE FOOT SWITCH, place the selector switch in the START position and power the
machine. Place the selector switch in the PUNCH or the SHEAR position and test the voltage between
terminal #’s 4, 5, 10 & ground. Test between terminal # 4 & ground to determine that there is voltage
present at the foot switch. The reading should be 110-220 volts. With the pedal up, the voltage should
read 110-120V between # 5 & ground. There should be no voltage reading between # 10 & ground. With
the pedal depressed, the voltage should read 110-120V between # 10 & ground. There should be no
voltage reading between # 5 & ground. If these readings are not correct, continue on with the following
steps:
A.
Turn the machine’s power off at the disconnect switch. Remove the cover on the foot switch and
check for any loose connections.
B.
Make sure that the switches are adjusted properly. You should hear two distinct "clicks"
approximately 1/2 inch (12mm) apart when depressing the pedal. There is a set screw adjustment
on the pedal shaft to adjust the switches.
C.
Check the switches with an Ohm meter.
9.
Damage to the foot pedal cord: Check the continuity of the wire in the cord with an Ohm meter.
Make sure that the power to the machine is off and locked out. The wires must be disconnected
from the pedal and the terminal blocks.
8.2 LIMIT SWITCH INSPECTION PROCEDURE
The limit switches are sealed units and cannot be taken apart. The plunger can be manually checked. It
should move freely in and out. The switches can also be tested with an Ohm meter. The wires must be
disconnected from the terminal blocks and the power to the machine must be turned off. With the
plunger out, the switch should read continuity; with the plunger depressed, it should read open.
8.3 CONTROL VALVE INSPECTION
THE MACHINE WILL TRAVEL IN ONLY ONE DIRECTION.
THIS COULD BE CAUSED BY:
A.
Contamination in the hydraulic oil which causes the spool to stick in one position: With the
machine’s power off, the spool of the valve can be manually shifted. On each end of the control
valve, there is a pin in the center of the knurled nut that holds the coil on. To shift the spool
manually, use a small punch or similar device to push these pins in by hand, first one and then,
the other. Turn the machine on and try it again. If the machine now operates, the hydraulic oil
and the filter should be changed.
B.
A defective coil on the control valve: The coils can be checked by using an Ohm meter. The wires
to the coils must be disconnected. If the ohm reading shows open, the coil is defective and must be
replaced.
Summary of Contents for 9012-24M
Page 10: ...Page 9 FIGURE 1 ...
Page 12: ...Page 11 FIGURE 2 ...
Page 16: ...Page 15 FIGURE 4A ...
Page 17: ...Page 16 FIGURE 4B ...
Page 18: ...Page 17 FIGURE 4C ...
Page 22: ...Page 21 FIGURE 6 ...
Page 24: ...Page 23 FIGURE 7 ...
Page 35: ...Page 34 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 40: ...Page 39 FIGURE 15 ...
Page 42: ...Page 41 FIGURE 16 ...
Page 48: ...Page 47 FIGURE 20 ...
Page 54: ...Page 53 FIGURE 24 ...
Page 56: ...Page 55 FIGURE 25 ...
Page 62: ...Page 61 FIGURE 27 ...
Page 66: ...Page 65 FIGURE 29 ...
Page 68: ...Page 67 FIGURE 30 ...
Page 74: ...Page 73 FIGURE 32 ...
Page 78: ...Page 77 FIGURE 34 ...
Page 80: ...Page 79 FIGURE 35 ...
Page 82: ...Page 81 FIGURE 36 ...
Page 84: ...Page 83 FIGURE 37 ...
Page 86: ...Page 85 FIGURE 38 ...
Page 90: ...Page 89 FIGURE 41 ...
Page 92: ...Page 91 FIGURE 42 ...
Page 93: ...Page 92 FIGURE 43 ...
Page 96: ...Page 95 THIS PAGE LEFT BLANK INTENTIONALLY ...
Page 98: ...Page 97 FIGURE 46 ...
Page 100: ...Page 99 FIGURE 47 ...